M&V S.r.l.
Via L. Guerra, 9
80040 Cercola (NA)
Ph./Fax +39 0815552428
e-mail:
© M&V S.r.l.
vesuvius userguide10 June 2015.doc
Page 18 of 24
Information Technology Solutions
V
ESUVIUS OWNERS MANUAL
Vesuvius Specifications
Weight
approx 24kg
Dimensions
415H x 368W x 510D
Brew boiler
0.8l - 1000W AISI 316L low corrosion stainless steel 2mm thick (8mm
end plates).
Steam boiler
1.5l - 1400W AISI 316L low corrosion stainless steel 2mm thick (8mm
end plates).
Max Pressure
12.5 bar E61 brew group limitation
Total Power Draw max
2.5Kw, detachable mains cord, 1500W with brew boiler priority &
sequential heating selected. Eco modes to reduce power consumption.
Pump & Motor
FG304 gear pump motor unit, brushless, 24V DC (4mm gears)
Water Tank Level Sensing
Capacitive (no magnets, sprung platforms or floats)
Water tank Capacity
2.9l to brim, normal fill 2.7 litres
Drip tray capacity
1.7l (can be drained)
Insulation
Both boilers
Useful Hot water draw
/- 200 ml (dead draw with machine switched off is 940ml)
Low Voltage Transformer
24V 110W, commercial unit.
Low water alarm
Visual only
Feet
Metal, height adjustable
Steam and hot water wands
Ball joint no burn. Steam on left, water on right
Portafilters
2, 1 single and 1 double spout
Filter baskets
1 single, 1 double, 1 blind
Plumbed or tanked operation
Pipes and drain hoses supplied, drip tray has drain facility. Electronic
switch to change from mains to plumbed
Pressure Profiling
5 profiles, each with up to 7 stages. Battery backup of stored profiles
and all system settings.
Brew Boiler Isolation and
selectable preheat
The brew boiler is always mechanically isolated from the steam boiler
HX unit, the water path only opens when brewing begins and closes
when brewing finishes. Preheat of brew water can be switched on or off
as desired, even if the steam boiler is on.
PID control
Independent PID algorithms for brew boiler, steam boiler & pump
Timer
7 day timer, with up to 2 on/off times each day.
Wooden accessory case
Containing various small spares, feet, 2 portafilters single & double
basket, blind filter, all hoses required for plumbing.
Pressure profiling
5 profiles can be saved each with up to 7 stages.
Last shot protection
The Vesuvius will always complete the last shot, even if water is low