Maintenance and care
55
Tensioning and changing V-belt
D
Remove fixing bolts
À
D
Remove lock-nut
Á
D
Adjust nut
Â
until V-belts have correct
tensions
D
Retighten lock-nut and fixing bolts
To replace the V-belts loosen lock-nut and
swing alternator inwards.
1
3
1
2
Alternator
The alternator is maintenance-free.
Nevertheless, it must be protected against dust and, above all, against moisture.
In order to avoid damage to the alternator, observe the following instructions:
While the engine is running
D
Do not de-energize the main battery switch!
D
Do not disconnect the battery or pole terminals or the cables!
D
If, durig operation, the battery charge lamp suddenly lights up, stop the engine im-
mediately and remedy the fault in the electrical system!
D
Do not run the engine unless the battery charge control is in satisfactory order!
D
Do not short-circuit the connections of the alternator with those of the regulator or said
connections with ground, not even by briefly bringing the connections into contact!
D
Do not operate the alternator without battery connection!
Temporary decommissioning of engines
Temporary anti-corrosion protection according to MAN works norm M 3069 is required for
engines which are to be put out of service for fairly long periods.
The works standard can be obtained from our After-Sales Service department in Nurem-
berg.