Commissioning and operation
31
Visual Quit / Test:
Standard function:
visual acknowledgement,
i.e. all flashing alarm texts in the currently visible alarm screen switch to
constant representation if the horn was acknowledged beforehand; the
red alarm LED integrated in the front plate is also switched from flashing
to continuous lighting. All other monitoring devices in the system are ac-
knowledged via the serial bus.
Test function if there is currently no alarm and / or all issued alarms have
been visually acknowledged beforehand:
Lamp test, i.e. the three LEDs
in the front plate are activated as long as the key is pressed.
Special function:
see explanation of key
+
-menu function:
Shift selection cursor to the right or increase input va-
lue.
RESET:
Standard function: The reset key can be used to reset a slow down or
stop alarm:
A reduction alarm can only be reset after reduction of the speed
below 800 rpm.
If the corresponding criteria have been met, horn and optics / test button
pressed / activated and the cause of the alarm eliminated, the reduction
or stop alarm in the central processing unit is reset.
Special function:
see explanation of key
−
-menu function:
Shift selection cursor to the left or decrease input value.
PAGE:
Standard function:
Switch to next highest display screen for analog en-
gine data. The page number is indicated in the top left-hand side of the
display with P1 to P4. Page 4 is followed again by page 1. If this key is
pressed while the alarm screen is on display, the monitor switches back
to the analog engine data from which the alarm screen was originally
called.
-
Special function:
Key enables setting of the LCD contrast with simulta-
neous pressing of the keys
T E S T
or
R E S ET
.
ALARMS:
Standard function:
Calling up the alarm screen; the five alarms or warn-
ings last issued and still present are displayed. At the top left of the moni-
tor is the code A1. If there are more than 5 messages issued, the mess-
ages can be displayed in groups of five by pressing the key again. The
page number is indicated in the top left with A1 to Ax. If the display jumps
to the 1st alarm screen or the display remains unchanged when the key
is pressed, no more messages are active.
Special function:
Holding the key for at least 5 seconds activates the
built-in configuration menu. There, the language, units, date and time
can be set.
Menu function:
Within the menu, this key has a cancel function (Esc).
The program moves back by one menu level and / or from the main
menu to the normal display function.
T E S T
P A G E
R E S ET
P A G E
P A G E
ALARMS
M en