Commissioning and operation
25
The D 2848 LE 401 is equipped with a monitoring and diagnostic system MMDS option-
ally.
On the control console and alternatively on other control stands, the following display de-
vices are available for monitoring operation:
1. Analog round instruments, see below
2. Display device MMDS-L, see page 26
3. Display device MMDS-LC, see page 28
4. Engine room panel MMDS-EP, see page 35
For operation and speed adjustment, MAN provides the following equipment:
5. Drive lever control system Mini Marex made by Mannesmann-Rexroth, see page 36
1. Round instruments
MAN can supply the following VDO round instruments for operation monitoring:
Revolution counter with integrated digital hours of operation counter
Oil pressure engine
0
−
6 bar
Oil pressure gearbox
0
−
25 bar
Oil temperature engine
50
−
150
°
C
Coolant temperature engine 40
−
120
°
C
Exhaust temperature engine 100
−
900
°
C
Voltmeter
18
−
32 V