Commissioning and operation
39
1. Engine speed synchronisation (only twin-engine systems)
2. Trolling
The “Syn./Trol.” key can be used to operate both functions in parallel, but not sim-
ultaneously.
Engine speed synchronisation
(only possible with twin-engine systems)
If the special function “Engine speed synchronisation” has been enabled in the setting
units, twin-engine systems provide the possibility to synchronise the engine speeds of
both drive engines. For both drive engines to run synchronously, an engine speed feed-
back signal from a speed sensor is required for each engine.
Pressing the “Syn./Trol.” key (press once) enables the “Engine speed synchro-
nisation” function. Pressing the key again (press once) disables the function once
again.
It is only possible to enable or disable the engine speed synchronisation on the
active control stand when both command master levers are in the engine speed
range “Forwards” or during the “Warming Up” function. Before exiting from these
areas, disable the “engine speed synchronisation”.
While the function is active, LED 4 “SYNCHRO” shows continuous light.
.
As soon as one of the command masters leaves the engine speed range “Forwards”
without terminating the synchronisation beforehand, it is switched off automatically.
In this case, the LED “SYNCHRO” flashes rapidly (approx. 0.2 seconds on / 0.2 sec-
onds off) and the acoustic signal transmitter issues a continuous tone at the active
control stand (this is not a fault alarm but a warning).
The second command master must then be set into the “Neutral” position to terminate
the warnings. The engine speed of the relevant command master is kept at idling
speed during this period.
While the control system is in the function “Synchronisation”, the engine speeds of both
power units can
only
be changed using the control lever of the “Master system”. If there
is a command change to another control stand, the active function “Engine speed syn-
chronisation” is also taken over onto the new control stand.
Trolling
If the special function “Trolling” has been enabled in the setting units, there is the possi-
bility to use the “Syn./Trol.” key to enable the trolling mode to continuously adjust the
clutch slip.
SYN/TROL
Содержание D 2848 LE 401
Страница 1: ...D 2848 LE 401 403 405 D 2840 LE 401 402 407 D 2842 LE 401 402 403 406 408 411 412 413 ...
Страница 2: ......
Страница 7: ...Declaration 9 ...
Страница 14: ...Commissioning and operation 16 Engine views D 2842 LE 401 1 2 3 9 10 11 7 4 5 6 8 12 14 13 15 17 18 16 19 ...
Страница 63: ......