6
53D0419
PRE-INSTALLATION INFORMATION
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS
PROPANE GAS
Manifold Press: (W.C.)
3.5"
Manifold Press: (W.C.)
10"
Maximum Supply Pressure 10.5"
Maximum Supply Pressure 13"
Minimum Supply Pressure 4.5"
Minimum Supply Pressure 11"
BEFORE yOU START
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incom-
plete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should
have the following:
• Fireplace (Firebox and Burner System)
• Rock Wool
• Log Set
• Lava Rock
•
Deflector Shield (to be used with Simpson Dura Vent Horizontal Termination - pn 985)
ITEMS REqUIRED FOR INSTALLATION
Tools:
Building Supplies:
• Phillips Screwdriver
• Framing Materials
• Hammer
• Wall Finishing Materials
• Saw and/or saber saw
• Caulking Material (Noncombustible)
• Level
• Fireplace Surround Material (Noncombustible)
• Measuring Tape
• Piping Complying with Local Codes
• Electric Drill and Bits
• Tee Joint
• Pliers
• Pipe Sealant Approved for use with Propane/LPG
• Square
(Resistant to Sulfur Compounds)
• Pipe Wrench
The classification “noncombustible material” includes,
but is not limited to stone, brick and mortar. Noncom-
bustibles are safe to overlay the black-painted metal
face (including radiant plates) and do not pose a fire
hazard. Do not allow any noncombustible finish material
to extend past or interfere with fireplace opening.
The classification “combustible material” includes, but
is not limited to plywood, drywall and particle board.
Combustible materials may contact the sides, bottom
or back of firebox. Do not overlay the black painted face
with combustible materials.
hIGh ELEVATIONS
Input ratings are shown in BTU per hour and are certi-
fied without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at eleva-
tions above 4,500 feet (1,370 m).
Model
Designer
Natural Propane
Max. BTU/hr Input
36,000
36,000
Min. BTU/hr Input
25,000
26,000
Orifice Size (as shipped)
#43
#54