16
53D0419
VENT INSTALLATION
A Minimum of 3"
Clearance to the Top
Is Required Along
Horizontal Length until
Flue Pipe Penetrates
Outside Wall.
W
ARNING
A Minimum 1"
Clearance to
Combustibles
Permitted All Around
Flue at Outside Wall
REAR VENT INSTALLATION
W
ARNING
This fireplace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.
W
ARNING
Horizontal sections of this vent system
require a minimum of 3" clearances to
combustibles at the top of the flue and 1"
clearance at the sides and bottom
until the
flue penetrates the outside wall.
A minimum
1" clearance all around the flue is acceptable
at this point of penetration.
Vertical sections of this vent system require
a minimum of 1" clearance to combustibles
on all sides of the pipe.
FP2041
design venting
10/08
Figure 12 -
Combustible Clearances for Vent Pipe
FP2041
Содержание Designer
Страница 52: ...52 53D0419 NOTES...
Страница 53: ...53D0419 53 NOTES...
Страница 54: ...54 53D0419 NOTES...
Страница 56: ...OCTOBER 2008 P N 63D0419 Rev 9 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...