53D9041
25
B36LA & B36RA Woodburning Fireplaces
������
���������������������
�����
GAS APPLIANCE INSTALLATION
CAUTION:
When using a gas appliance, the fire-
place damper must be set in fully open position.
Figure 29
Outer Fireplace Wrap
Inner Fireplace Wrap
Side Brick
26” Max.
Fireplace Firebrick
Hearth Brick
Gas Line Access Tube
Repack Insulation Around
Gas Line Where it Passes
Through Gas Line Access
Tube for Proper Seal
Maintain 1/2”
Minimum Air
Space Clearance
to Combustibles
for Gas Line Out
to 4” From Side
of the Fireplace
Combustible Materi-
als May Be Located
at Zero Clearance
to Gas Line Beyond
4” From Fireplace
Side.
Back Refractory
Brick
Side Refractory
Brick
Dimple
Installation of Gas Appliance in Fireplace
TRIM INSTALLATION
The face of your fireplace may be left exposed or trimmed with any noncombustible material such
as brick, stone or marble.
Figure 30.
If a noncombustible trim is installed, be sure it is fastened
snugly to the face of the fireplace. A crack between the material and the face of the fireplace could
pose a fire hazard and impair the proper operation of the fireplace. Blocking the fireplace with fram-
ing and attaching the base to the supporting floor will further reduce the possibility of such a crack
developing.
CAUTION:
Do not allow any trim materials to extend closer than 3/8” to the vertical edges of the
firebox opening if you plan to equip the fireplace with glass doors.
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the
mortar joints of masonry trim.
Combustible material must not be installed below the top spacers of the fireplace or overlap the
sides of the fireplace face. Seal the face of the fireplace to the surrounding wall with noncombus-
tible caulk or trim materials to prevent cold air leakage around the fireplace.
CAUTION:
No trim should block or restrict in any way the flow of air into the air inlets in the face of
the fireplace.
Figures 30 and 31
Be sure to provide the required floor protection as described in a preceding section of this manual.
Page 13,
Figure 10
Combustible mantels and trim must be installed in accordance with the National Fire Protection
Association - ANSI NFPA 211 Standard - Section 7-2.3.3.
Glass Door Installation
This fireplace has been tested and listed for use with Model MGD36B or MGD36PB glass doors.
For installation of the Model MGD36B or MGD36PB glass doors, refer to the instructions provided
with the doors.