53D9041
7
B36LA & B36RA Woodburning Fireplaces
������
��������������
FIREPLACE FEATURES
Figure 2 - Residential Installation -
Using “E” Series Triple Wall Thermosyphoning Chimney Components
Model LF-CC-1 or LF-CCL-1
Round Termination Cap
Roof Flashing Model 612
14 ft. = Min. Height (No offsets)
14 ft. = Min. Height (2 30° Elbows)
21 ft. = Min. Height (4 30° Elbows)
86 ft. = Max. Height (Chimney support
every 30 ft.)
Firestop Model LF-FS-2
(requires 17” x 17” Opening)
Flexible Duct
Type FP-4-U
Combustion Air Assembly
Model OAC4
Nail to Framing Members
Bottom of Fireplace
Chimney 2” Min. Air space
Clearance to Combustibles
Chimney Section -
E12 (1 ft. pipe)
E18 (18” pipe)
E36 (3 ft. pipe)
E48 (4 ft. pipe)
Top Spacer
Glass Doors - Model WB36LR
Galvanized Metal Strip
CAUTION:
Do not block
air inlets or outlets
See NOTE
NOTE:
Combustible materials should not be installed below top spacer. Noncombustible materials
such as brick or tile may be used to trim face of the fireplace but should not cover any portion of the
louvered panel or cool air inlet.
Combustibles must not overlap the black painted face of the fireplace.
FP2159
Flue Outlet Height
Storm Collar
22
¹⁄₂
”
37
⁵⁄₈
”
38
¹⁄₂
”