B36LA & B36RA Woodburning Fireplaces
“E” CHIMNEY COMPONENTS
������
�����������������
1. When installing “E” series triple wall chimney system on the B36LA and B36LR, do not mix chimney
system components other than those listed below.
2. Maintain 2” airspace clearance to combustibles.
3. Use same offset and rise chart for chimney when installing elbows.
Model Number Description
E48
4-foot chimney section (8-inch diameter flue)
E36
3-foot chimney section (8-inch diameter flue)
E18
1
1
/
2
-foot chimney section (8-inch diameter flue)
E12
1-foot chimney section (8-inch diameter flue)
EE30
30° elbows (package contains two 8-inch diameter elbows). One pair is required for each offset.
Maximum - two pairs (4 elbows) per chimney.
ECS
Chimney support (required when chimney height exceeds 30 feet)
LFCC-1
Round chimney cap for contemporary installations. Includes storm collar.
LFCCL-1
Round termination cap for chase installation (includes inlet air telescope)
612
0-6/12 pitch flashing for contemporary installation. One required with SC round chimney cap on
0-6/12 pitch roof
1212
6/12 - 12/12 pitch flashing for contemporary installation. One required with SC round chimney
cap on 6/12 - 12/12 pitch roof
LF-FS-2
17” firestop spacer - One required at each ceiling or floor level below 20 foot chimney height
LF-FS-30
Firestop spacer - for 30° chimney incline through ceiling or floor
LFSQT
Square termination for chase installation. Model T8 telescope assembly requried but not included
T8
Telescoping assembly for use with telescoping chimney caps
LF-FF
Flat flashing for chase installation (36” x 72”)