B36LA & B36RA Woodburning Fireplaces

MAINTENANCE & SAFETY

Fuel Storage

Wood can be dried sufficiently for burning within a few weeks if protected form rain in a low humid-
ity area.  It is far better to cut wood and allow it to dry for a year.  In all cases, the wood should be 
stacked so that both ends of the sticks are exposed to the air and protected from rain.  The drier 
the wood, the more usable heat produced by the fire and less likely rapid accumulation of soot and 
creosote within the chimney is to occur.  See the section of this manual concerning chimney main-
tenance for information concerning the hazards of soot a creosote accumulation.  Small quantities 
of wood required for fire tending must be kept at least 30 inches from the fireplace.

Disposal Of Ashes

Ashes should be placed in a metal container with a tight fitting lid.  The closed container of ashes 
should be placed on a noncombustible floor or on the ground well away from all combustible ma-
terials pending final disposal.  If the ashes are disposed of by burial in soil or otherwise locally 
dispersed, they should be retained in the closed container until all cinder has thoroughly cooled.  
Ashes should never be placed in a container with combustible materials.

Chimney Maintenance

Creosote, Formation and Need for Removal:  When wood is burned slowly, it produces tar and 
other organic vapors, which combine with expelled moisture to form creosote.  The creosote vapors 
condense in the relatively cool chimney flue of a slow-burning fire.  As a result, creosote residue 
accumulates on the flue lining.  When ignited, this creosote makes an extremely hot fire.
The chimney should be inspected at least twice a year during the heating season to determine if a 
creosote buildup has occurred.
If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
The chimney cap can be removed for inspection, maintenance and cleaning by removing three 
screws from the support legs and lifting upward.
When the fireplace is first  in use, inspect the chimney frequently and clean the chimney any time an 
accumulation is observed on the flue walls.  The frequency of these inspections can be increased 
or reduced appropriately after a pattern of accumulation has been established.  Please note, how-
ever, that changes in the outside environmental conditions such as temperature and humidity or 
changes in the operation of the fireplace can lead to rapid buildup of soot and/or creosote.
To clean the chimney, obtain the services of a qualified and reputable chimney sweep, or remove 
the accumulation with brushes on wooden or fiberglass poles.  Do not use metal pipes, chains, 
wires, etc., to clean the chimney because such items can scratch the surface of the stainless steel 
flue which can shorten the life of the flue and provide a rough surface for soot particles to attach 
to.
Be sure to cover nearby furnishing and arrange some method of catching soot and creosote parti-
cles that may fall during the chimney cleaning process.  If glass doors are installed on the fireplace, 
they should be closed.  Extra caution must be used to avoid damage to the flue damper during the 
cleaning process.
In addition to checking and cleaning the chimney on a regular basis, be sure to inspect the chimney 
before starting a fire at the beginning of each heating season.  Make sure the chimney is clear from 
any accumulation of soot, creosote or any other debris, and that all joints are intact.
MHSC does not recommend chemical cleaners because some may contain elements that corrode 
the metal parts of the chimney or fireplace.

Содержание B36LA

Страница 1: ...esidential Installation 36 Built in Wood Burning Corner Fireplace with Optional Outside Air and Glass Doors WARNING This replace has not been tested with an unvented gas log set To reduce risk of re o...

Страница 2: ...No 211 Some codes may require the replace and chimney be electrically grounded Before beginning the installation you should check with local building of cials to obtain required permits and assure com...

Страница 3: ...tended for supplemental heating only and is not intended for use as a primary heating system The replace is designed to sit directly on a combustible oor The replace must be installed with clearances...

Страница 4: ...iew the precautions and recommendations in the section of this manual pertaining to outside combustion air assembly The replace is also equipped with a ue damper which must be open when the replace is...

Страница 5: ...ace Clearance to Combustibles Chimney Section S12 1 ft pipe S18 18 pipe S36 3 ft pipe S48 4 ft pipe Top Spacer Zero Clearance to Combustibles at Side Spacers Glass Doors Model WB36LR Galvanized Sheet...

Страница 6: ...30 feet SC Round chimney cap for contemporary installations Includes storm collar SCL Round telescoping chimney cap SQL8 Square telescoping chimney cap 612 0 6 12 pitch ashing for contemporary instal...

Страница 7: ...on Air Assembly Model OAC4 Nail to Framing Members Bottom of Fireplace Chimney 2 Min Air space Clearance to Combustibles Chimney Section E12 1 ft pipe E18 18 pipe E36 3 ft pipe E48 4 ft pipe Top Space...

Страница 8: ...ows per chimney ECS Chimney support required when chimney height exceeds 30 feet LFCC 1 Round chimney cap for contemporary installations Includes storm collar LFCCL 1 Round termination cap for chase i...

Страница 9: ...ng size required at the roof level table 1 should be used as a guide for sizing the roof opening Proper selection of a chimney outlet location is also important Objects such as overhanging or nearby t...

Страница 10: ...n the hearth extension and the face of the replace To help prevent the crack from developing the hearth extension materials must be rmly fastened in place Wall ties should be screwed to the face of th...

Страница 11: ...I658 Clearance from Fireplace Opening to Sidewall When Wall Shield IS NOT Used C36RA or B36RA Hearth Extension Model I627 Hearth Extension Model I658 Minimum Clearance from Fireplace Opening to Sidew...

Страница 12: ...orm Collar Included with Chimney Cap Flashing 612 or 1212 Roof Joist Shields Attic Space Refer to Table 1 for Roof Opening Size FS Firestop Spacer 14 x 14 Framed Opening 1 Clearance to Com bustibles w...

Страница 13: ...quare Hole in Joist 1 MCear ance to Combus tibles When Using FS Firestop Max Installation Height 86 14 Square Hoel in Joist 2 Min Air Space Clear ance Between Chimney and combustibles Firestop Spacer...

Страница 14: ...his in struction manual 3 Set the replace in the desired location and be sure it is securely supported and leveled Install metal safety strip for hearth extension as shown by Figures 10 11 and 12 Chec...

Страница 15: ...odel C36RMA B36RA with RLK Louver kit WB36LR Glass Door and OAC6 Combustion Air Model C36LMA not shown same as above except uses LLK Louver Kit on the B36LA replace Cool Air Inlet WB36LR Glass Door Ga...

Страница 16: ...ith a plumb line as shown by Figure 15 The replace should be located in the planned installation position After the center line is established and a nail is driven to mark the point the opening can be...

Страница 17: ...ling Joist Flue Pipe Firestop Spacer Chimney Section Header Firestop Spacer Installation at Floor Levels Floor Joist Inlet Air Pipe Flue Pipe Firestop Spacer Chimney Section Header Table 1 Minimum Req...

Страница 18: ...y are as follows If the total height of the replace and chim ney is 16 0 or more two elbows may be used in the chimney 21 0 or more four elbows may be used in the chimney 4 The inclined portions of ch...

Страница 19: ...use of FS Firestop FP2169 Figure 20 For Triple Wall Elbows Bench tab Over FP2168 Figure 19 Collar Bracket Table 2 Select desired offset and read across Table to obtain rise quan tity of chimney secti...

Страница 20: ...14 x 14 Maximum four 4 elbows Per Fire place Offset Max 10 Support Straps Diagonal Chimney Enclosure Vertical Chimney Enclosure Recommended Diagonal Chimney Enclosure Acceptable Fasten All Support Str...

Страница 21: ...ibe Line at Bottom FP1897 Model SC SCL Round Chimney Cap Apply Mastic Here Storm Collar Flashing 36 Min 18 Dim 7 FP2171 chimney cap install FP2171 Figure 23 5 Nail the ashing securely in place with ei...

Страница 22: ...ated at an exterior location which is not likely to be accidentally blocked in any manner The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion a...

Страница 23: ...cking screw down and tighten it with a screwdriver or nutdriver Figure 27 10 Nail or screw the combustion air assembly to the surface of the wall NOTE If the wall covering is brick or stone use approp...

Страница 24: ...rohibit or place restrictions on the use of gas appliances in replaces Check with local code authorities before proceeding with the installation 5 The gas appliance and all connecting gas piping shoul...

Страница 25: ...ng and attaching the base to the supporting oor will further reduce the possibility of such a crack developing CAUTION Do not allow any trim materials to extend closer than 3 8 to the vertical edges o...

Страница 26: ...w Top Edge of Fireplace Combustible Mantel Top Edge of Fireplace 18 Min From Fireplace Opening to Bottom of Combustible Mantel Manufacturer Recommendation Top Edge of Fireplace Opening Top of Fireplac...

Страница 27: ...How To Build A Better Fire The rst three res should be of moderate size to allow the replace to adjust and the bricks to cure before being subjected to larger res First make sure your room is well ven...

Страница 28: ...air pollution but can induce extreme irritation for some individuals Use hemlock spruce juniper and other resinous woods with caution They contain moisture pockets which upon heating pop with conside...

Страница 29: ...g the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney re The chimney cap can be removed for inspection m...

Страница 30: ...m the face of the replace only with noncombustible materials 5 Do attach the noncombustible face trim material rmly to the face of the replace 6 Do block in or fasten the replace to prevent the possib...

Страница 31: ...ore or place ammable liquids gases or pressurized containers near the replace 17 Don t neglect to instruct all responsible persons in the proper and safe operation of the replace 18 Don t fail to inst...

Страница 32: ...s KY 40361 www mhsc com Item Description Qty B36RA B36LA 1 Retainer Side Brick 1 020270 020270 2 Retainer 2 Z19901 Z19901 3a Firebrick Side Assy Right 1 014012 3b Firebrick Side Assy Left 1 021663 4 R...

Страница 33: ...53D9041 33 B36LA B36RA Woodburning Fireplaces...

Страница 34: ...34 53D9041 B36LA B36RA Woodburning Fireplaces...

Страница 35: ...your local building code contains restrictions on the use of this replace before you purchase it Blowers or fans which are warranted separately Heat loss due to the passage of heat or air through or a...

Страница 36: ...JANUARY 2009 53D9041 Rev 2 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: