53D9041
B36LA & B36RA Woodburning Fireplaces
FIREPLACE INSTALLATION
Figure 5
39”
6” Min.
FP2162
brick or stone hearth extension
Fireplace
Hearth
Do Not Block Air
Inlet Openings
Safety Strip Required
When Unit is Placed on
Combustible Floor or
Pratform
58” or 54” if Wall
Shield is Used
FP2162
Alternate Brick or Stone Hearth
Extensions for use with the B36LA,
B36RA, C36LA & C36RA Fireplace
������
��������������������
Figure 6
Single Story Installation
with Attic Space
Chimney Cap
3’ Min.
Storm Collar
(Included with
Chimney Cap)
Flashing (612
or 1212)
Roof Joist
Shields
Attic Space
Refer to Table
1 for Roof
Opening Size
FS Firestop Spacer 14
¹⁄₂
”
x 14
¹⁄₂
” Framed Opening
1
³⁄₄
” Clearance to Com-
bustibles with FS Firestop
“S” Series Chimney
2” Min. Air Space
Clearance Between
Combsutibles and
Chimney
13’ Min.
FP2163
������
��������������
Figure 7
Installation of Shields with MHSC End Open Fireplace
and “S” Series Chimney
Roof Joists Shields - Secure to Top of Chase Top
Opening Before the Chase Top Flashing is Installed
14
¹⁄₂
” Min.
Chase Top Installation
14
¹⁄₂
” Min.
Secure Shields to
the Roof as shown
Before Installing the
Roof flashing on a
Conventional Roof
Conventional Roof Installation
FP2164