Manual XRD600 REG English
8
5.
Comissioning
5.1
Measuring procedure
(AdaptivDIM)
NOTE - During calibration, the connected
lights may flicker. This is system-condi
-
tioned and not a defect of the device. The
calibration must be completed and can not
be interrupted by switching off the device.
The maximum load is possible up to an ambient
temperature of 50 ° C. Between 50 ° C and 70 ° C,
the power is reduced by 15 watts / ° C, please con
-
sider this during installation.
5.2
Power rating of retrofit dimmers
Load type cutting method
Power output in percent
Calculated power load
Ohmic
trailing edge
approx. 100% of the rated power
600 VA
LED
trailing edge
approx. 70% of the rated power
420 VA
LED
leading edge
approx. 20% of the rated power
120 VA
As a rule:
Example 28x 4W (rated power LED) + 20% power factor = 135 VA power to be processed. Specifi
-
cations depend on the light source used and may vary upwards and downwards.
When starting up for the first time (voltage is ap
-
plied to the device for the first time after installa
-
tion), the dimmer will start a measuring procedure
and calibrate accordingly to the connected load.
For minor calibration, the dimmer decides which
cutting method ( leading or trailing edge) is used
and adjusts itself to load type 3 or 4.
Should a new calibration be required by changing
the light source or to set a different load type, the
device must be recalibrated, for a new calibration
see 7.