Manual XRD600 REG English
16
8.5 Excerpt from technical data
Rated Voltage
Connected Load
Power loss
Standby - 0,75W; Operation at full load - 1,8W
DMX512 / DMX RDM
1 DMX channel; power supply via external power supply unit
12 - 24V DC is required
parallel connection of modules possible
Alternative Ansteuerung
Push button input
(Universal voltage)
12...230V AC oder DC
Detailed technical data can be found in the data sheet of the product.
8.4 Operating notes
8.4.3. Noise emission
It may occur that the dimmers cause acoustic noi
-
se when they are not used under unfavourable
conditions or with certain consumers.
Make sure the phases are evenly balanced.
8.4.4. Flickering
The dimmer requires a faultless mains, flickering
may occur in case of mains supply fluctuations or
ripple control signals as well as during calibration.
This circumstance is system related and not a de-
fect of the device.
8.4.1. Derating
In the event of over temperature, an automatic
derating occurs (status derating is indicated by the
LED), which means that the dimmer‘s power is re
-
duced and the load dimmed down.
8.4.2. Short circuit
Automatic shutdown in the event of a short circuit.
Every 30 sec. it is tested whether the short circuit
is still present. As soon as the short circuit is eli
-
minated, an automatic restart takes place. If the
error is still present after 5 min, the device is swit
-
ched off completely.
Turn off the power and remove the error.