Start new measument with the device button
To activate, release the button
within
these 2 sec-
onds, a flashing pattern follows and the parameter
will be processed. If the button is released outside
this 2 sec. window, the programming will be ter
-
minated.
Parameter Load / Function
Features
1
any load
Automatic calibration - the load type is determined automatically, dimming
parameters are set automatically and the dimming curve is adjusted to achie
-
ve the best possible dimming result
Dimmmode
2
; Dimming curve (linear characteristic)
3 *
; Dimming curve (fixed LED curve) * Factory setting
4
; Dimming curve (automatic)
5
; Dimming curve (fixed)
6
corridor mode
7
Reset
reset to factory default settings
Select a parameter from below table.
To leave a set corridor mode, it is necessary to perform
a factory reset.
Programming must be done within the
first 60min after power-on.
The key must be released within the active
phase for each parameter (as long as the
LED is on).
Some situations may require a re-measuring of
the dimmer, e.g. if the load is changed or the load
type is modified. To start programming, press and
hold the device button
or push button
.
After 20 sec. the programming mode starts (LED
and load turns off), each parameter is indicated
by a flashing of the LED and load for 2 seconds.