8.  Operation via DMX

8.1  Preparation

According to the DMX standard, no more than 32 

DMX devices (with separate power supply) should 

be connected to a DMX signal. Then the DMX sig

-

nal must be amplified with a repeater. To supply 

the bus, a supply voltage of 12 - 24V DC must be 

present (current consumption per module <7mA).

If your controller has a masterfader or overall vo

-

lume control, make sure that the DMX value 255 

(Max. Level) is adjustable, otherwise no program

-

ming can be performed. 

A  value  from  1  to  512  can  be  assigned  as  start 

address. In the delivery state, the start address (of 

the device) is preset to 1.  The module uses one 

DMX channel.

For example, perform a factory reset:

Press one of the two buttons (device button 

 

or push button 

,

 after 20 seconds the LED il

-

luminates  for  2  seconds,  which  shows  phase  1. 

Hold the button pressed in, phase 6 is followed by 

a slightly longer pause until phase 7 is activated. 

During these 2 seconds of the activated phase the 

push button must be released.

The dimmer is now reset to the factory settings.

To operate a device with DMX, a DMX512 control

-

ler is required. A gateway can also be used to crea

-

te an interface to other protocols such as KNX... 

A supply voltage of 24V DC must be available (cur

-

rent consumption per module <7mA). Within the  

DMX protocol, a correct clamping of the signal line 

with + 24V and -GND must be ensured.

NOTE - Before operating the dimmer, it is 

necessary to send a DMX signal once. As 

long as the DMX input is used (DMX signal 

is  transmitted),  the  device  button  and 

push button inputs are not active. One se

-

cond  after  the  last  DMX  signal  has  been 

received, the button inputs are reactivated 

again.

Содержание XRD600 REG

Страница 1: ...XRD600 REG DMX Retrofit Dimmer Item No 10 252 XRD600 REG Valid from Version Hardware H2 Firmware F2 2 0 Document Date 07 04 2020 Document 10252_MA_en_A4_XRD600REG Manual ...

Страница 2: ...g 8 5 1 Measuring procedure AdaptivDIM 8 5 2 Power rating of retrofit dimmers 8 6 Operation via buttons 9 6 1 Device button 9 6 2 Push button input Universal voltage input 9 6 3 Functions push button operation 9 6 4 Set Min level push button 10 6 5 Commissioning and diagnosis 11 7 Start new measument with the device button 12 8 Operation via DMX 13 8 1 Preparation 13 8 2 Assign DMX start address 1...

Страница 3: ...ces on the market they comply with the EU directives in the version valid for the respective device Declarations of conformity are available for all products The CE marking is marked on the devices and is shown in the applicable documents Danger The interior and the connectors of the amplifier holds hazardous voltages The unit must only be installed and serviced by a proven electrican specialist i...

Страница 4: ...g this maintronic product and the trust you have placed in us We the team of maintronic wish you a lot of fun with this product 2 2 About this Document Due to continuous product development some of the information may not be complete and up to date The information in this document is subject to change without prior notice Please check our website www maintronic de if there is a newer version 2 3 C...

Страница 5: ... naires Solid in dry and clean environment Only approved for indoor use Installation in switch cabinets top hat rail in a junction box with insulated enclosure Access is only possible with tools Only operate on 1 phase with 230V AC With a back up fuse of max 16A 3 2 Functions and features DMX retrofit universal dimmer Control via DMX RDM or push button input Load types LED retrofit NV halogen lamp...

Страница 6: ...x or small distributor in sulated enclosure Top connections X1 L 1 Load output N 4 Neutral conductor L 2 Input Voltage 230V AC T 5 Push button input GND N N 3 Neutral conductor T 6 Push button input 12 230V Bottom connections X2 24V 7 24V DC DMX 9 DMX DMX RDM Signal DMX 8 DMX DMX RDM Signal GND 10 24V DMX Shield Operating elements and indicators 1 Device button Commissioning Programming 2 Status L...

Страница 7: ...www maintronic de info maintronic com 7 Fig 3 Connection diagram with push button 24 VDC Fig 2 Connection diagram with push button 230 VAC 4 1 3 Connection diagram ...

Страница 8: ...the rated power 600 VA LED trailing edge approx 70 of the rated power 420 VA LED leading edge approx 20 of the rated power 120 VA As a rule Example 28x 4W rated power LED 20 power factor 135 VA power to be processed Specifi cations depend on the light source used and may vary upwards and downwards When starting up for the first time voltage is ap plied to the device for the first time after instal...

Страница 9: ...nd will be recalled at next power up 6 2 Push button input Universal voltage input It is possible to operate and program the device via the device button NOTE Operation with the device button is only possible within the first 60 minutes after Power On and will be deactivated after 60 minutes The device is equipped with a push button input T on which standard 230V AC buttons can be connected Both D...

Страница 10: ...ively the min level can be configured via DMX see 9 3 In case of a flickering load or if the load remains too bright the in level the lowest dimming value can be adjusted via a push button connected to the push button input Perform the configuration with the following steps ...

Страница 11: ...ible with the select ed dimming mode the system switches to a com patible mode 6 5 2 Determine load no max number of lamps of the same type In order to optimally use the dimmer and to see how many luminaires of the same type can be used it is possible to determine the load number of the luminaire To do this measure with a single luminaire After the measurement the load type is displayed and afterw...

Страница 12: ...teristic 3 Dimming curve fixed LED curve Factory setting 4 Dimming curve automatic 5 Dimming curve fixed 6 corridor mode 7 Reset reset to factory default settings Select a parameter from below table To leave a set corridor mode it is necessary to perform a factory reset Programming must be done within the first 60min after power on The key must be released within the active phase for each paramete...

Страница 13: ...s device button or push button after 20 seconds the LED il luminates for 2 seconds which shows phase 1 Hold the button pressed in phase 6 is followed by a slightly longer pause until phase 7 is activated During these 2 seconds of the activated phase the push button must be released The dimmer is now reset to the factory settings To operate a device with DMX a DMX512 control ler is required A gatew...

Страница 14: ...w DMX start address This is indicated by two long flashes of the LED and possibly connected lights go to 100 brightness for about one second Afterwards the programming mode is exited NOTE If the programming does not take place after 10 minutes the programming mode will be exited and the device is back in normal operation The module can display the currently con figured DMX address via the LED To d...

Страница 15: ...utton 2 seconds load jumps to 0 and 100 for half a second each then the LED flashes consistently 2 Select the desired parameter by pressing the button again Again a parameter change is in dicated by the output level 0 and 100 as at start The flashing pattern is then indicated by a long light followed by a brief flash of the LED 3 Set the fader of the desired parameter 4 To save press the device bu...

Страница 16: ...ke sure the phases are evenly balanced 8 4 4 Flickering The dimmer requires a faultless mains flickering may occur in case of mains supply fluctuations or ripple control signals as well as during calibration This circumstance is system related and not a de fect of the device 8 4 1 Derating In the event of over temperature an automatic derating occurs status derating is indicated by the LED which m...

Страница 17: ...lying the operating voltage Standby O During operation with switched off channel Output Switched On OOOOOOOOOOOOOOOOOOOO Switched on the brightness of the LED depends on the output level Receive bus event O O DMX telegram received Operation via push button input OOOO OO DMX input button is pressed mains voltage is present Programming mode OOOOO OOOOO DMX identification display ready for load calib...

Страница 18: ...Carl Zeiss Str 10 14 97424 Schweinfurt Germany Tel 49 0 9721 7766 0 Fax 49 0 9721 7766 18 www maintronic de info maintronic de ...

Отзывы: