Mounting | UK
41
Connecting RLS 45 O
RLS 45 O
room air control is used to activate
PPB 30 O
units.
1.
Take off frame of room air control.
2. Connect the PPBs according to the wiring
diagram (
Appendix).
i
The exhaust air function is only possi
-
ble if a PPB 30 O is connected (service
mode setting for unit type = PPB 30 O
and number of units = 1).
3. Insert room air control in the re-
cessed-mounted box and screw down to
recessed-mounted box with 2 screws.
4. Fit frame. Ensure that the sensor opening
is above the PP 45 HYI (if fitted) and that
the frame engages.
5. Start up ventilation system
Chapter 10.
Connecting RLS 45 K
RLS 45 K
room air control is used to activate
PPB 30 O
or
PPB 30 K
units.
1.
Take off frame of room air control.
2. Connect
PPB 30 O
to the RLS 45's FAN1
and FAN 2 connection terminals. Connect
PPB 30 K
units to RS 485 bus.
i
The power supply to the PPB 30 K
(+) MUST come from the Fan1 or
Fan2 connection. Connect accord
-
ing to wiring diagram (
Appendix).
i
A combination of
PPB30 O and PP 45
units
is not permitted at the FAN1 and
FAN2 connection terminals of the RLS
control.
i
No exhaust air function is possible
for
PPB 30 O
units on an RLS 45 K
control.
i
If a PPB 30
K
unit is running in ex
-
haust air mode, the PP 45/PPB 30 O
units handle the volumetric flow com
-
pensation at the fan interface (Fan1/
Fan2). It is important that the unit type
+ quantity are set correctly.
3. Insert room air control in the recessed-
mounted box and screw down to re
-
cessed-mounted box with 2 screws.
4. Fit frame. Ensure that the sensor opening
is above the PP 45 HYI (if fitted) and that
the frame engages.
5. Start up ventilation system
Chapter 10.
9.8 Mounting radio switch (EnOcean)
i
When radio mode is activated,
EnOcean radio components, such as
master or slave units or sensors, can
be taught-in directly on ventilation units.
For range of radio components
Technical data.
Purely
radio-
controlled
system
Combi system
DS 45 RC
+
PP 45 RC
PP 45 RC
PPB 30 RC
...
RLS 45 K
+
max. 6
PP 45 K
PP 45 O
or
max. 3
PPB 30 O/K
PP 45 EO
+
PP 45 RC
PPB 30 RC
Purely radio-controlled PushPull system
1. Simply glue DS 45 RC to installation
location on the wall. Alternatively, the radio
switch can also be screwed onto the wall
(mounting material provided by customer).
2. Use the "Learn button" to activate tea-
ching-in mode on the ventilation unit. For
more information about teaching-in
Operating instructions, chapter 7.
3.
For basic unit settings, such as "Block Off
function"
Installation instructions.