46
Magtrol WB/PB Dynamometers
Chapter 2 – Installation / Mounting
2.1.5
WB/PB 15 S
erieS
WB/PB 15 Series Dynamometers are fitted with a mechanical stator assembly locking device
protecting the load cell during transport. After installing the dynamometer on the test bench, proceed
as follows and refer to
figure 2–5
to unlock the system:
1, Screw the nuts
on each side of the dynamometer with three turns.
2, Unscrew the nuts
on each side of the dynamometer until they touch the nuts
. A
minimum clearance of 0.4 mm between the nuts
and the dynamometer locking device is
requested.
Note:
The WB/PB 15 Series Dynamometers are not fitted with overload
protection systems. The load cell
is strong enough to cope with
any overload occurring during normal dynamometer use.
Figure 2–5 WB/PB 15 Load Cell Locking System
w
arning
:
w
hen
the
dynamometer
is
loCked
during
transport
,
the
load
Cell
should
not
be
under
meChaniCal
stress
(
Compression
or
traCtion
).