Service Policy

Owners of MAGNETROL may request the return of a
control or any part of a control for complete rebuilding
or replacement. They will be rebuilt or replaced promptly.
Controls  returned  under  our  service  policy  must  be
returned by Prepaid transportation. MAGNETROL will
repair or replace the control at no cost to the purchaser
(or owner) other than transportation if:

1.  Returned within the warranty period; and
2.  The factory inspection finds the cause of the claim

to be covered under the warranty.

If the trouble is the result of conditions beyond our con-
trol;  or,  is  NOT  covered  by  the  warranty,  there  will  be
charges  for  labor  and  the  parts  required  to  rebuild  or
replace the equipment.

In  some  cases  it  may  be  expedient  to  ship  replacement
parts;  or,  in  extreme  cases  a  complete  new  control,  to
replace  the  original  equipment  before  it  is  returned.  If
this is desired, notify the factory of both the model and
serial  numbers  of  the  control  to  be  replaced.  In  such
cases, credit for the materials returned will be determined
on the basis of the applicability of our warranty.

No claims for misapplication, labor, direct or consequen-
tial damage will be allowed.

Return Material Procedure

So that we may efficiently process any materials that are
returned,  it  is  essential  that  a  “Return  Material
Authorization”  (RMA)  number  be  obtained  from  the
 factory,  prior  to  the  material’s  return.  This  is  available
through a MAGNETROL local representative or by con-
tacting the factory. Please supply the following information: 

1.  Company Name
2.  Description of Material
3.  Serial Number
4.  Reason for Return
5.  Application

Any  unit  that  was  used  in  a  process  must  be  properly
cleaned in accordance with OSHA standards, before it is
returned to the factory.

A Material Safety Data Sheet (MSDS) must accompany
material that was used in any media.

All shipments returned to the factory must be by prepaid
transportation.

All replacements will be shipped F.O.B. factory.

ASSURED QUALITY & SERVICE COST LESS

Magnetrol & Magnetrol logotype are registered trademarks of Magnetrol International, Incorporated.
Hastelloy is a registered trademark of Haynes International, Inc.

Содержание C29

Страница 1: ...Float Actuated Liquid Level Switches Flanged External Cage Installation and Operating Manual...

Страница 2: ...used in a manner not specified by manufacturer protection provided by equipment may be impaired Notice of Copyright and Limitations Magne tr ol Magne tr ol logotype and are registered trademarks of M...

Страница 3: ...4 1 Recommended Practice 13 4 1 1 Keep control clean 13 4 1 2 Inspect switch mechanisms terminals and connections monthly 13 4 1 3 Inspect entire unit periodically 14 4 2 What To Avoid 14 5 0 Specific...

Страница 4: ...level alarm for maximum protection 1 3 Piping An instruction tag secured to the control gives dimensional data on switch actuating levels referenced from center line of upper side tank connection Posi...

Страница 5: ...e units are shipped from the factory with the enclosing tube tightened and the switch housing set screw locked to the enclosing tube Failure to loosen the set screw prior to repositioning the supply a...

Страница 6: ...housing cover NOTE It is the responsibility of the customer to comply with applica ble installation codes and practices Class I Division 1 locations may contain explosive gas mixtures Appropriate pre...

Страница 7: ...ing or breaking an electrical circuit Refer to Figure 4 As the liquid level falls the float drops and moves the attraction sleeve out of the magnetic field releasing the switch mechanism magnet The te...

Страница 8: ...NOTE To widen the differential by one inch the lower jam nuts must be set proportionately lower on the stem i e in this example by 1 inch 2 Make sure power source is turned off 3 Unscrew and remove s...

Страница 9: ...he base of the switch housing Rotate switch housing to correct position and tighten set screws Refer to Figure 1 on page 5 Caution After increasing gap setting be certain to check for proper operation...

Страница 10: ...A and readjust new assembly to the previously determined level differential settings See Switch Differential Adjustment Section 2 4 5 Replace new float and stem assembly into head flange and install n...

Страница 11: ...r to the control 2 Remove switch housing cover 3 Disconnect power wiring from switch assembly 4 Swing magnet assembly in and out by hand to check care fully for any sign of binding Assembly should req...

Страница 12: ...dium line connections to switch housing 5 Perform system shutdown to relieve pressure from float chamber of control Allow unit to cool 6 Close shutoff valves if equipped to isolate control from vessel...

Страница 13: ...reventive Maintenance Periodic inspections are necessary to keep your level control in good working order This control is a safety device to protect the valuable equipment it serves A systematic progr...

Страница 14: ...ation may eventually crack or become loose at connections causing leakage Check lines and connec tions carefully and repair or replace if necessary NOTE As a matter of good practice spare switches sho...

Страница 15: ...listed as TYPE 4X 7 9 Class I Div 1 Group B Class II Div 1 Groups E F G ATEX IEC Ex All with an electric switch mechanism and an ATEX II 2 G EEx d IIC T6 ATEX housing 94 9 EC IEC Ex Ex d IIC T6 IP 66...

Страница 16: ...2 Flanged Side Side Actuating Levels A B C A B C A B C HL LL A B C A B C A B C HL LL C29 76 9 75 3 44 14 38 13 81 6 87 18 38 14 46 6 87 19 06 2 02 2 92 247 87 365 350 174 466 367 174 484 51 74 D30 65...

Страница 17: ...78 96 8 46 215 Side Side Flanged Conduit Connections D Electrical Switches TYPE 4X 7 9 1 NPT Group B 1 NPT Pneumatic Switches TYPE 1 1 4 NPT NOTES 1 Switch actuating levels HL LL are given for minimu...

Страница 18: ...ete control less float chamber 10 bolts 7 and nuts 8 089 6567 003 Series Type Bulletin Dry contact B C D 42 683 Hermetically sealed F 42 683 Hermetically sealed HS 42 694 Bleed type pneumatic J 42 685...

Страница 19: ...osing tube kit includes items 4 and 5 089 5933 004 089 5933 011 Enclosing tube gasket 012 1204 001 012 1301 002 Head flange kit includes items 5 6 7 8 and 9 089 4206 001 089 4206 002 Flange gasket 012...

Страница 20: ...Model and serial number of control B Replacement assembly kit part number 19 18 20 11 10 9 4 2 14 3 12 5 8 7 6 13 1 15 17 16 6 2 Tandem Flanged External Cage Models 1 Housing cover 2 Housing base 3 Sw...

Страница 21: ...des items 9 10 11 12 13 14 and 15 Lower float and stem kit Special order includes items 9 16 17 18 and 19 Float chamber kit Special order includes items 7 8 9 and 20 D30 TDM J30 TDM L30 TDM 6 2 5 Mode...

Страница 22: ...TION TYPE AND SIZE PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Connection flanges are ASME B16 5 raised face Electric switch mechanism and enclosure codes on next page Models are limited to maximum tempe...

Страница 23: ...G9 Series HS Hermetically Sealed 5 amp Snap Switch with Wiring Leads 50 to 550 46 to 288 SPDT 1 HMJ HMK HMJ HMK 2 HMN HMP HMN HMP DPDT 1 HMS HMT HMS HMT 2 HMY HMZ HMY HMZ Series HS Hermetically Sealed...

Страница 24: ...turned If this is desired notify the factory of both the model and serial numbers of the control to be replaced In such cases credit for the materials returned will be determined on the basis of the a...

Отзывы: