46-605 Flanged External Cage Float Actuated Liquid Level Switches

5.2

Physical

CHAMBERS WITH 1-INCH CONNECTIONS
INCHES

MILLIMETERS

CHAMBERS WITH 2-INCH CONNECTIONS
INCHES

MILLIMETERS

CHAMBERS WITH 1

1

2

-INCH CONNECTIONS

INCHES

MILLIMETERS

Min.

Sp.

Gr.

1" NPT Threaded

& Socket Weld

1" Flanged

Upper Side/Bottom

1" Flanged

Side/Side

Actuating

Levels

1" NPT Threaded

& Socket Weld

1" Flanged

Upper Side/Bottom

1" Flanged

Side/Side

Actuating

Levels

A

B

C

A

B

C

A

B

C

HL

LL

A

B

C

A

B

C

A

B

C

HL

LL

C29 .76

9.94

3.02 13.50 12.81 5.87 16.44 13.46 5.87 17.06 2.95 3.85 252

76

342

325

149

417

341 149 433

74

97

D30 .65

9.19

3.27  12.75 12.06 6.12 15.63 12.71 6.12 16.25 2.50 3.33 233

83

323

306

155

155

322 155 412

63

84

J30

.48

10.19

4.33 14.63 13.06 7.18 17.50 13.71 7.18 18.19

2.61 3.34

258

109

371

331

182

182

348 182 462

66

84

L30

.40

3.24 3.98

82

101

B60 .68

9.81

3.80 14.25 12.68 6.68 17.12 13.33 6.68 17.75

2.77 3.44

249

96

361

322

169

434

338 169 450

70

87

C60 .55

2.87 3.60

72

91

Min.

Sp.

Gr.

1

1

2

" NPT Threaded

& Socket Weld

1

1

2

" Flanged

Upper Side/Bottom

1

1

2

" Flanged

Side/Side

Actuating

Levels

1

1

2

" NPT Threaded

& Socket Weld

1

1

2

" Flanged

Upper Side/Bottom

1

1

2

" Flanged

Side/Side

Actuating

Levels

A

B

C

A

B

C

A

B

C

HL

LL

A

B

C

A

B

C

A

B

C

HL

LL

C29 .76

9.75 3.44 14.38 13.81 6.87 18.38 14.46 6.87 19.06 2.02 2.92 247

87

365

350

174

466

367 174 484

51

74

D30 .65

9.00 3.69  13.12 13.06 7.12 17.19 13.71 7.12 17.88 1.87 2.70 228

93

333

331

180

436

348 180 454

47

68

J30

.48

10.00 4.75 15.06 14.06 8.18 19.12 14.71 8.18 19.75

1.97 2.70

254

120

382

357

207

485

374 207 501

50

68

L30

.40

2.60 3.34

66

84

B60 .68

9.62 4.22 14.69 13.68 7.68 18.75 14.33 7.68 19.38

1.46 2.13

244

107

373

347

195

476

383 195 492

37

54

C60 .55

1.93 2.66

49

67

Min.

Sp.

Gr.

2" NPT Threaded

& Socket Weld

2" Flanged

Upper Side/Bottom

2" Flanged

Side/Side

Actuating

Levels

2" NPT Threaded

& Socket Weld

2" Flanged

Upper Side/Bottom

2" Flanged

Side/Side

Actuating

Levels

A

B

C

A

B

C

A

B

C

HL

LL

A

B

C

A

B

C

A

B

C

HL

LL

C29 .76 10.00 3.56 14.44 13.81 6.87 18.25 14.46 6.87 18.94 2.07 2.97 254

90

366

350

174

463

367 174 481

52

75

D30 .65

8.75 3.81  13.25 13.06 7.12 17.56 13.71 7.12 18.25 1.50 2.33 222

96

336

331

180

446

348 180 463

38

59

J30

.48

9.74 4.87 15.19 14.06 8.18 19.50 14.71 8.18 20.12

1.60 2.33

247

123

385

357

207

495

374 207 511

40

59

L30

.40

2.23 2.97

56

75

B60 .68

9.38 4.34 14.81 13.68 7.68 19.12 14.33 7.68 19.75

1.52 2.19

238

110

376

347

195

485

363 195 501

38

55

C60 .55

1.99 2.72

50

69

Levels ± 0.25" (6 mm)

Levels ± 0.25" (6 mm)

Levels ± 0.25" (6 mm)

Содержание C29

Страница 1: ...Float Actuated Liquid Level Switches Flanged External Cage Installation and Operating Manual...

Страница 2: ...used in a manner not specified by manufacturer protection provided by equipment may be impaired Notice of Copyright and Limitations Magne tr ol Magne tr ol logotype and are registered trademarks of M...

Страница 3: ...4 1 Recommended Practice 13 4 1 1 Keep control clean 13 4 1 2 Inspect switch mechanisms terminals and connections monthly 13 4 1 3 Inspect entire unit periodically 14 4 2 What To Avoid 14 5 0 Specific...

Страница 4: ...level alarm for maximum protection 1 3 Piping An instruction tag secured to the control gives dimensional data on switch actuating levels referenced from center line of upper side tank connection Posi...

Страница 5: ...e units are shipped from the factory with the enclosing tube tightened and the switch housing set screw locked to the enclosing tube Failure to loosen the set screw prior to repositioning the supply a...

Страница 6: ...housing cover NOTE It is the responsibility of the customer to comply with applica ble installation codes and practices Class I Division 1 locations may contain explosive gas mixtures Appropriate pre...

Страница 7: ...ing or breaking an electrical circuit Refer to Figure 4 As the liquid level falls the float drops and moves the attraction sleeve out of the magnetic field releasing the switch mechanism magnet The te...

Страница 8: ...NOTE To widen the differential by one inch the lower jam nuts must be set proportionately lower on the stem i e in this example by 1 inch 2 Make sure power source is turned off 3 Unscrew and remove s...

Страница 9: ...he base of the switch housing Rotate switch housing to correct position and tighten set screws Refer to Figure 1 on page 5 Caution After increasing gap setting be certain to check for proper operation...

Страница 10: ...A and readjust new assembly to the previously determined level differential settings See Switch Differential Adjustment Section 2 4 5 Replace new float and stem assembly into head flange and install n...

Страница 11: ...r to the control 2 Remove switch housing cover 3 Disconnect power wiring from switch assembly 4 Swing magnet assembly in and out by hand to check care fully for any sign of binding Assembly should req...

Страница 12: ...dium line connections to switch housing 5 Perform system shutdown to relieve pressure from float chamber of control Allow unit to cool 6 Close shutoff valves if equipped to isolate control from vessel...

Страница 13: ...reventive Maintenance Periodic inspections are necessary to keep your level control in good working order This control is a safety device to protect the valuable equipment it serves A systematic progr...

Страница 14: ...ation may eventually crack or become loose at connections causing leakage Check lines and connec tions carefully and repair or replace if necessary NOTE As a matter of good practice spare switches sho...

Страница 15: ...listed as TYPE 4X 7 9 Class I Div 1 Group B Class II Div 1 Groups E F G ATEX IEC Ex All with an electric switch mechanism and an ATEX II 2 G EEx d IIC T6 ATEX housing 94 9 EC IEC Ex Ex d IIC T6 IP 66...

Страница 16: ...2 Flanged Side Side Actuating Levels A B C A B C A B C HL LL A B C A B C A B C HL LL C29 76 9 75 3 44 14 38 13 81 6 87 18 38 14 46 6 87 19 06 2 02 2 92 247 87 365 350 174 466 367 174 484 51 74 D30 65...

Страница 17: ...78 96 8 46 215 Side Side Flanged Conduit Connections D Electrical Switches TYPE 4X 7 9 1 NPT Group B 1 NPT Pneumatic Switches TYPE 1 1 4 NPT NOTES 1 Switch actuating levels HL LL are given for minimu...

Страница 18: ...ete control less float chamber 10 bolts 7 and nuts 8 089 6567 003 Series Type Bulletin Dry contact B C D 42 683 Hermetically sealed F 42 683 Hermetically sealed HS 42 694 Bleed type pneumatic J 42 685...

Страница 19: ...osing tube kit includes items 4 and 5 089 5933 004 089 5933 011 Enclosing tube gasket 012 1204 001 012 1301 002 Head flange kit includes items 5 6 7 8 and 9 089 4206 001 089 4206 002 Flange gasket 012...

Страница 20: ...Model and serial number of control B Replacement assembly kit part number 19 18 20 11 10 9 4 2 14 3 12 5 8 7 6 13 1 15 17 16 6 2 Tandem Flanged External Cage Models 1 Housing cover 2 Housing base 3 Sw...

Страница 21: ...des items 9 10 11 12 13 14 and 15 Lower float and stem kit Special order includes items 9 16 17 18 and 19 Float chamber kit Special order includes items 7 8 9 and 20 D30 TDM J30 TDM L30 TDM 6 2 5 Mode...

Страница 22: ...TION TYPE AND SIZE PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Connection flanges are ASME B16 5 raised face Electric switch mechanism and enclosure codes on next page Models are limited to maximum tempe...

Страница 23: ...G9 Series HS Hermetically Sealed 5 amp Snap Switch with Wiring Leads 50 to 550 46 to 288 SPDT 1 HMJ HMK HMJ HMK 2 HMN HMP HMN HMP DPDT 1 HMS HMT HMS HMT 2 HMY HMZ HMY HMZ Series HS Hermetically Sealed...

Страница 24: ...turned If this is desired notify the factory of both the model and serial numbers of the control to be replaced In such cases credit for the materials returned will be determined on the basis of the a...

Отзывы: