Section 4 – Installation (continued)
Telemotive TR12 inteleSmart Receiver Instruction Manual – 03/01/07
12
6. Wiring of the system should now be
complete. Install antenna.
7. Turn switch SW2 OFF (MR relay
control) and SW1 ON (main power
switch). Stand clear of the crane and
apply AC power to receiver unit. Check
to see if at least the three green LEDs
DS1, DS2 and DS3 are ON, as well the
red RF Receiver ON LED (other LEDs
may be ON also). If none are lit check
AC power and power switch SW1. See
Figure 8-1. Receiver Layout for switch
and LED locations.
NOTE
WHEN FIRST APPLING POWER TO THE
UNIT YOU MUST WAIT 10 SECONDS FOR
THE RECEIVER TO GO THROUGH THE
PROGRAMMING MODE.
8. Wait 10 seconds and turn the
transmitter ON. Check to see if the red
LEDs DS30 and DS32 are now ON. At
this point the MR relay is disabled; the
functions of the transmitter can be
checked by noting the turning ON of the
appropriate red LEDs next to the
control relays (K1-K12). After checking
out the functions, turn switch SW2 ON
to enable the MR relay (red LED DS31
should now turn ON), check function
and direction by jogging each motion.
Installation should now be complete.
9. If there are any problems see Section 8 -
Servicing.
Figure 4-2. Receiver Mounting Details
Figure 4-1. Input Power Connections.
120V N GRN
J1
1
Drawing not to scale.
7.87”
200 mm
.30” DIA.
7.5 mm
hole 4 places
11.02”
279.9 mm
11.81”
300 mm
7.09”
180 m
m
Overall Cabinet Depth
With door
closed inches
With door
closed mm
With door
open inches
With door open
mm
Cabinet 5.26
133.60
12.12
307.98