6
-130
Multi-function Contact Input Functions (H1-01 to H1-10)
Speed Control (ASR) Gain Adjustment for Vector Control
Use the following procedure to adjust C5-01 and C5-03 with the mechanical system and actual load con-
nected.
Setting
Value
Function
Control Methods
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
D
Speed control disable setting for V/f control with PG
OFF: Use speed control V/f control with PG
ON: Do not use speed control for V/f control with PG
No
Yes
No
No
No
E
Speed control integral reset
Enables switching between PI and P control for the speed control loop.
No
No
No
Yes
Yes
77
Speed control (ASR) proportional gain switch (switching between C5-01 and C5-03)
OFF: Use proportional gain in C5-01
ON: Use proportional gain in C5-03
No
No
No
Yes
Yes
At zero-speed, increase C5-01
(ASR P Gain 1) until there is no oscillation.
At zero-speed, decrease C5-02
(ASR I Time 1) until there is no oscillation.
Does oscillation develop when the motor
operates at the maximum normal operating
speed?
Decrease C5-01 (ASR P Gain 1).
Increase C5-02 (ASR I Time 1).
YES
NO
Adjustment completed.
(When there is higher-level position control,