8.5. Flex EX 6 output relay contact diagram
•
Numbers in circles: wire or Harting pin number.
•
For 12 – 24 VDC power supply, wire #1 corresponds to the negative charge (–) and wire #3 corresponds to the
positive charge (+). Wire #2 is for GROUND.
•
After initiating the START function the START position will become an auxiliary function with momentary contact –
relay FUNC.
•
If the built-in horn is enabled it is not possible to use relay FUNC (K26), contacts #4 and #5 are not connected to the
output cable.