4.2.6 Lights Indicator and Buzzer Installation
The miniature lights indicator and buzzer can be easily
fitted onto the receiver enclosure. If the buzzer is installed
it will sound for up to 3 seconds when the START button is
initially pressed (manufacture preset to HORN function).
The same START button becomes a momentary output
thereafter. When the receiver MAIN relays are activated,
the buzzer is also activated. Make sure the buzzer is
connected to the K30 Function output relay CN11 port
located on the AC line filter/relay board inside the receiver.
The indicator light should be wired into K25. This function
relay is preset so that the indicator light will remain active anytime the MAIN relays are active as
well. Please contact a Magnetek representative if you would like the lights indicator or the buzzer
to work differently than described above.
4.2.7 Other Function Output Relays Settings
Listed below are other types of functions that can be outputted through the two Function output
relays (K25 and K26) via the infrared IR programmer unit. Please contact a Magnetek representative
for more details.
LV
→
Function relay closes when receiver voltage is low.
ID
→
Function relay works simultaneously with all motion commands.
NORMAL
→
START fu AUX with normal momentary output.
TOGGGLE
→
START fu AUX with toggled/latching output.
EXT
→
Function relay works simultaneously with the receiver MAIN relays.
TDM A+B
→
Function relay closes when selector switch is rotated to the A+B position and opens
when rotate to A or B positions (tandem monitoring output).
HORN
→
Function relay closes for up to 3 seconds when START command is initiated at transmitter
power on and then becomes a normal momentary output thereafter.