Flex 4Base® CE Instruction Manual
January 2017
Page 29 of 41
4.2.4 Jumper Settings
Jumper setting applies to functions such as the standard or reversed logic A/B selector
sequence, cable-free configurations, transmitter inline pushbutton
configurations, firmware version, system testing and remote pairing
methods.
Jumper Settings
Function
JP2
(Inserted)
Pressing the START button is required when receiver MAIN relays
are deactivated (cancels ANY button setting on Section 4.1.4).
JP3
(Opened)
Standard A/B selector sequence
- Output
relay A activated at A position, output relay B activated at B position,
both relays activated at A+B position.
JP3
(Inserted)
Reversed logic A/B selector sequence
- Output
relay B activated at A position, output relay A activated at B position,
both relays deactivated at A+B position.
JP4
(Inserted)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB4
JP6
(Inserted)
Display system firmware version
JP7
(Inserted)
For system testing only (receiver MAIN relays disabled)
JP8
(Opened)
Receiver-to-transmitter remote pairing
(pressing the Pairing button required)
JP8
(Inserted)
Receiver-to-transmitter remote pairing
(pressing the Pairing button not required)
4.2.5 Fuse Ratings
FUSE # 110~120VAC 220~240VAC 380~400VAC 410~460VAC 24VAC
42 &
48VAC
9~36VDC
F3 ~ F10
5.0A 5.0A 5.0A 5.0A 5.0A
5.0A
5.0A
F1 ~ F2
0.5A 0.5A 0.5A 0.5A 1.0A
1.0A
2.0A