F1
F/R2
R1
R1
F1
F/R2
4.2.2 Output Relay Configurations
4.2.2.1 Output Relay Types
1. 2 output relays per motion – single speed only
Output relays with Forward (F) and Reverse (R) 1
st
speed only.
2. 3 output relays per motion – shared 2
nd
speed output relay
Output relays with Forward 1
st
speed (F1), Reverse 1
st
speed (R1) and Forward/Reverse 2
nd
speed
(F/R2). Forward and Reverse 2
nd
speed (F/R2) shared the same output relay.
3. 4 output relays per motion – separate 1
st
and 2
nd
speed output relays
Output relays with Forward 1
st
speed (F1), Reverse 1
st
speed (R1), Forward 2
nd
speed (F2) and
Reverse 2
nd
speed (R2). Forward and Reverse 2
nd
speed are separate output relays.
4.2.2.2 Output Relay Actions at 2
nd
Speed
1. 3 output relays configuration with Closed/Closed contact at 2
nd
speed
F1 (or R1) output relay closed at 1
st
speed and F1 + F/R2 (or R1 + F/R2) output relays closed
at 2
nd
speed. Refer to Section 4.2.3.1 on how to set to this function.
Forward 1
st
speed pushbutton pressed
Forward 2
nd
speed pushbutton pressed
↓
↓