Start-Up Guideline
1
Start Up Guideline
1. Mechanically mount all the parts as explained in Mechanical Mounting Instructions on page 6.
Connect the encoder and proximity sensor to the drive as explained in Encoder Electrical
Connection on page 8 and Proximity Sensor Electrical Connection on page 8.
2. Then if not already pre-loaded, set all the drive parameters to parameters that are
recommended by the car controller manufacturer so the drive and controller can interface with
each other correctly; this includes all parameters in the A1
– A5 submenu and C1 – C4
submenus.
3. Proceed to PM Drive Setup Procedure on page 9 to continue with setting of motor data,
Encoder Pulses, rotor alignment, and auto-tune.
4. Refer to Troubleshooting on page 16 if there are some initial start-up problems for Axial Flux
specific problems ONLY. For general faults on the HPV900 Series 2, refer to the HPV900
Series 2 Technical Manual TM7333
NOTE: All the parts needed to get the Axial Flux drive to run are outlined on page 3 (need drive
part number HPV900-_ _ _ _-2E1-02 and kit 46S04444-_ _ _ _ )
NOTE: If the motor has a shaft, use a shaft mounted encoder. If a shaft mounted encoder is to be
used, a standard HPV900 Series 2 is recommended.