Axial Flux Drive Models
2
Drive Model Number
HPV 900 Series 2 Drive Ratings
Rated
Input
Voltage
NA
1
Rated
HP
EU
1
Rated
HP
NA
1
Rated
kW
EU
1
Rated
kW
Overload
Selection
2
Carrier
Frequency
(kHz)
3
Continuous
Output Current
General
Purpose Rating
Continuous
Output Current
Elevator Duty
Cycle Rating
Maximum
Output
Current
for 5 Sec
Frame
Size
Model Number
7.5
--
5.5
--
250%
10
25
29
63
2
HPV900-2025-2E1-02
200%
8
31
33
10
--
7.5
--
250%
10
31
36
78
2
HPV900-2031-2E1-02
200%
8
39
41
2
15
--
11
--
250%
10
41
48
103
3.5
HPV900-2041-2E1-02
3
200%
8
51
55
0
20
--
15
--
250%
10
52
60
130
3.5
HPV900-2052-2E1-02
V
200%
8
65
70
25
--
19
--
250%
10
75
87
187.5
4
HPV900-2075-2E1-02
30
--
22
--
250%
10
88
102
220
4
HPV900-2088-2E1-02
40
--
30
--
250%
10
98
114
245
5
HPV900-2098-2E1-02
5
5
3.7
3.7
250%
10
8
9
20
1
HPV900-4008-2E1-02
200%
8
10
11
7.5
5.5
5.5
4
250%
10
12
14
30
2
HPV900-4012-2E1-02
200%
8
15
16
10
7.5
7.5
5.5
250%
10
16
19
40
2
HPV900-4016-2E1-02
200%
8
20
21
15
10
11
7.5
250%
10
21
24
53
3
HPV900-4021-2E1-02
200%
8
26
28
4
20
15
15
11
250%
10
27
31
68
3
HPV900-4027-2E1-02
6
200%
8
34
36
0
25
20
19
15
250%
10
34
39
85
4
HPV900-4034-2E1-02
V
200%
8
43
45
30
25
22
18.5
250%
10
41
48
103
4
HPV900-4041-2E1-02
200%
8
51
55
40
30
30
22
250%
10
52
60
130
4
HPV900-4052-2E1-02
200%
8
65
70
50
40
37
30
250%
10
65
75
162.5
5
HPV900-4065-2E1-02
60
50
45
37
250%
10
72
84
180
5
HPV900-4072-2E1-02
75
60
56
45
250%
10
96
111
240
5
HPV900-4096-2E1-02
Table 1: HPV900 Series 2 Drive Ratings
NOTE:
all ratings at 60/50Hz bases on a geared elevator application
1.
NA refers to drives sold in North America and ratings are based off of 460VAC input.
EU refers to drives sold in Europe and are based off of 400VAC input
2.
Based on Overload Select (C1) parameter selection
3.
Maximum Carrier Frequency before derating
HPV900
-
-
-
drive
input voltage
2 = 230 volt
4 = 460 volt
continuous
output current
operator style
E = Elevator
N = no operator
software program
1 = Standard Software
2 = PM Axial Flux
2 1
2
0