21 / 33
Certain modes are only available when the Transmitter is in S1 mode or
when two Transmitters, one in S1 mode and the second on S2 mode
are connected to the ends of the same cable. A transmitter in S2 mode
only does not allow core identification in open-circuit or short-circuit. This
kind of utilization automatically appears when two transmitters in S1 and
S2 mode are connected to the same cable and that this cable is cut after
pre-identification.
3.2.1.1.Pre-identification mode
A pre-identification sensor for all type of cable (JPRX_SAB_100)
.
Mode only usable with a transmitter in S1 mode or two transmitters in
S1 and S2 mode.
Connect the sensor to the receiver, the pre-identification light
illuminates.
Place the sensor on the cable, so that the groove under the
sensor fits around the cable.
Press the « measurement » button, the «
end of
measurement
» light turns off.
Wait for the result (6 seconds) without moving the sensor,
the «
end of measurement
» light illuminates and if the cable
is pre-identified, then the YES LED illuminates.
If the cable is not pre-identified, repeat the operation on other
points of the cable with 10cm of distance between them.