17 / 33
3.1.5.Fuse
The protection fuse is located on the underside of the housing.
In case of deterioration, it must be replaced by a strictly identical fuse:
5A 250VAC fast 5x20mm (breaking capacity >= 50A) or the transmitter
unit must be returned to after-sales service.
JUPITER X RECEIVER
The JUPITER X Receiver assembly consists of:
The Receiver to which are connected the sensors
Inductive sensor for identification
Probes for core identification and continuity with open circuit.
Flexible
Identifying
loops
for
short-circuited
core
identification
On option: a double flexible loop for core identification on a 4
conductor LV cable.
The Receiver and its sensors are supplied in a carrying case, which
itself fits into the lid of the Transmitter case.
The JUPITER X Receiver is used to
identify
a cable of which the
extremities are in short-circuit and earthed, to
identify the cores
in an
open or closed circuit
cable.
This is done in normal operation on
unpowered
HV & LV networks.
The JUPITER X Receiver is equipped with sensors dedicated to each
function to « extract » the signals emitted by the JUPITER X
Transmitter.
The results obtained, by the Receiver, require no interpretation, the
detection