215333
307
Revision A
Problem
Solution
Refer to
Symptom: Breakage of conditioner drive belt
Improper belt tension
Adjust conditioner drive belt tension.
4.5.10 Conditioner Drive Belt, page 254
Belt not in proper groove in pulley
Move belt to proper groove.
4.5.10 Conditioner Drive Belt, page 254
Foreign object between rolls
Disengage rotary disc pull-type and
stop engine. When all moving parts
have completely stopped, remove
foreign object.
3.20 Unplugging the Rotary Disc Pull-
Type, page 116
Belt pulleys and idlers misaligned
Align pulleys and idler.
4.5.10 Conditioner Drive Belt, page 254
Symptom: Machine pulling to one side
Rotary disc pull-type dragging on one
end and pulling to that side
Adjust rotary disc pull-type flotation
on both ends.
Low tire pressure on one side
Check and correct tire pressure
(207 kPa [30 psi]).
4.5.14 Wheels and Tires, page 270
Symptom: Disc does not start when engaging power take-off (PTO)
Mud on cutterbar
Remove mud from cutterbar. Do not
allow mud to dry on cutterbar.
3.20 Unplugging the Rotary Disc Pull-
Type, page 116
Primary driveline not connected
Connect driveline.
4.5.4 Primary Driveline, page 226
Symptom: Transport control box is not working and transport function will not activate
Control box
’
s 10 amp fuse has failed
Ensure all electrical connections in the
control box are secure. If necessary,
replace the fuse in the control box.
Contact your Dealer