Setting the Hydraulic Overload Pressure
NOTE:
•
This procedure requires installation of the optional pressure sensor (MD #B5574). For overload pressure
values, refer to pressure sensor installation instructions (MD #169031).
•
To enable sensor, refer to
Switching the Installed Header Sensors ON or OFF, page 134
.
1009974
C###
X###
WINDROWER SETUP?
NO/YES
A
B
C
Figure 3.80: M205 CDM Programming Buttons
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the
upper line.
•
NO/YES is displayed on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? is displayed.
1009991
OVERLOAD PRESSURE?
4000 PSI
C###
X###
D
C
B
A
Figure 3.81: M205 Hydraulic Overload Pressure
4.
Press SELECT (D) until OVERLOAD PRESSURE? is
displayed on the upper line.
•
The current overload pressure is displayed on
lower line.
NOTE:
Pressure range is 17,237
–
34,474 kPa (2500
–
5000 psi).
5.
Press left (B) or right (C) arrows to set hydraulic
overload pressure. Press SELECT (D).
6.
Press PROGRAM (A) to exit programming mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Содержание M205
Страница 3: ...Declaration of Conformity 1025029 ...
Страница 4: ...1025030 ...
Страница 20: ......
Страница 36: ...214603 16 Revision A Figure 1 23 Safety Signs Right Cab Forward Side 1011020 A B C D E F G H J K L M SAFETY ...
Страница 401: ...214603 381 Revision A Fuse Box Decal Figure 5 175 Fuse Decal 1022431 MAINTENANCE AND SERVICING ...
Страница 440: ......
Страница 462: ......
Страница 511: ...windshield wipers 56 INDEX ...
Страница 512: ......