Setting the Rotary Disc Overload Speed
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header. For more information, refer to
•
The recommended disc overload speed is 75% of disc speed. For more information refer to the rotary disc
header operator
’
s manual to determine proper overload speed.
1009974
C###
X###
WINDROWER SETUP?
NO/YES
A
B
C
Figure 3.78: M205 CDM Programming Buttons
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the upper
line. NO/YES is displayed on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? is displayed.
1009988
DISC OVERLOAD SPD?
-300 RPM
C###
X###
D
C
B
A
Figure 3.79: M205 Disc Overload Speed
4.
Press SELECT (D) until DISC OVERLOAD SPD? is
displayed on the upper line.
•
The current overload speed is displayed on the
lower line.
NOTE:
Default setting is -300 rpm. Range is -500 to -100 rpm.
5.
Press left (B) or right (C) arrows to set disc overload
speed. Press SELECT (D).
6.
Press PROGRAM (A) to exit programming mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Содержание M205
Страница 3: ...Declaration of Conformity 1025029 ...
Страница 4: ...1025030 ...
Страница 20: ......
Страница 36: ...214603 16 Revision A Figure 1 23 Safety Signs Right Cab Forward Side 1011020 A B C D E F G H J K L M SAFETY ...
Страница 401: ...214603 381 Revision A Fuse Box Decal Figure 5 175 Fuse Decal 1022431 MAINTENANCE AND SERVICING ...
Страница 440: ......
Страница 462: ......
Страница 511: ...windshield wipers 56 INDEX ...
Страница 512: ......