OPERATOR’S STATION
Cab-Forward, Engine Running, Header Engaged, Auger Header Index Switch ON
Scroll through display with cab display module (CDM) switch or ground speed lever (GSL) switch.
Display (Lower or Upper Line)
Description
#####.# ENGINE HRS
Total engine operating time.
#####.# HEADER HRS
Total Header operating time.
##.# ACRES/HOUR
##.# HECTARES/HOUR (If Metric)
Actual cutting rate in acres (hectares)/hour.
###.# SUB ACRES
###.# SUB HECTARES (If Metric)
Area cut since last reset. To reset, display SUB ACRES
on lower line, and hold down program switch until display
resets 5–7 seconds).
###### TOTAL ACRES
###### TOTAL HECT (If Metric)
Total area cut by machine.
##.## ##.# REEL IND.
##.## REEL SENSOR
Reel Peripheral speed along with ground speed in mph
or km/h.
Sensor disabled. IND and SENSOR alternate at 1 second
intervals.
##.# AUGER SPEED
##.# AUGER SENSOR
Auger rotational speed (4.7–9.9).
Sensor disabled. SPEED and SENSOR alternate at
1 second intervals.
#### KNIFE SPEED
#### KNIFE SENSOR
Knife speed In strokes per minute.
Sensor disabled. SPEED and SENSOR alternate at
1 second intervals.
##.# HEADER HEIGHT
##.# HEADER SENSOR
Distance setting (00.0–10.0) between cutterbar and ground.
Sensor disabled. HEIGHT and SENSOR alternate at
1 second intervals.
##.# HEADER ANGLE
##.# TILT SENSOR
Angle setting (00.0–10.0) header relative to ground.
Sensor disabled. ANGLE and SENSOR alternate at
1 second intervals.
##.# L FLOAT R ##.#
FLOAT SENS DISABLED (If Sensor Disabled)
Left and right
fl
oat setting (0.0–10.0).
Sensor disabled.
LOAD|
■■■■
| | ####
Bar graph representing hydraulic operating pressure.
Full scale Is preprogrammed overload pressure
(2500–5000 psi). If sensor disabled, LOAD does not
display
6
### °C or F HYD OIL TEMP
### °C or F HYD TEMP
Hydraulic oil temperature.
Sensor Disabled. TEMP and SENSOR alternate at
1 second intervals.
6.
The LOAD sensor to monitor knife/conditioner circuit pressure is optional. To monitor reel/auger circuit pressure,
relocate sensor as per Form MD #169031, which is available through your Dealer.
147649
79
Revision A
Содержание M155
Страница 3: ...Declaration of Conformity Figure 1 Declaration of Conformity Page 1 of 2 147649 i Revision A ...
Страница 4: ...Figure 2 Declaration of Conformity Page 2 of 2 147649 ii Revision A ...
Страница 30: ...SAFETY Figure 1 21 Safety Signs Left Cab forward Side 147649 14 Revision A ...
Страница 32: ...SAFETY Figure 1 23 Safety Signs Right Cab forward Side 147649 16 Revision A ...
Страница 44: ......
Страница 54: ......
Страница 320: ......
Страница 414: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 178 Fuse Decal 147649 398 Revision A ...
Страница 468: ......
Страница 509: ......