OPERATOR’S STATION
Forcing a Header ID
The header must be attached to the windrower to troubleshoot certain issues. If damage has occurred to the
header wiring or no header is available, you can force the windrower control module (WCM) to read a header ID.
The WCM reverts to reading NO HEADER each time the engine ignition is cycled.
IMPORTANT:
Forcing a Header ID that is different from the attached header can damage the windrower and header.
Doing so can lead to vibration, belt failures, and other over-speeding related problems.
1. Turn ignition key to RUN, or start the engine.
2. Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER SETUP? is displayed on the
upper line.
Figure 3.168: M155 CDM Programming Buttons
3. Press SELECT (B) until DIAGNOSTIC MODE? is
displayed in upper line.
• NO/YES is displayed on the lower line.
4. Press right (A) arrow to select Yes. Press SELECT (B).
Figure 3.169: M155 Diagnostic Functions
147649
134
Revision A
Содержание M155
Страница 3: ...Declaration of Conformity Figure 1 Declaration of Conformity Page 1 of 2 147649 i Revision A ...
Страница 4: ...Figure 2 Declaration of Conformity Page 2 of 2 147649 ii Revision A ...
Страница 30: ...SAFETY Figure 1 21 Safety Signs Left Cab forward Side 147649 14 Revision A ...
Страница 32: ...SAFETY Figure 1 23 Safety Signs Right Cab forward Side 147649 16 Revision A ...
Страница 44: ......
Страница 54: ......
Страница 320: ......
Страница 414: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 178 Fuse Decal 147649 398 Revision A ...
Страница 468: ......
Страница 509: ......