background image

214143

2

Revision F

1.2

General Safety

1000004

Figure 1.1: Safety Equipment

CAUTION

The following general farm safety precautions should be part of
your operating procedure for all types of machinery.

Protect yourself.

When assembling, operating, and servicing machinery, wear
all protective clothing and personal safety devices that could
be necessary for the job at hand. Do

NOT

take chances. You

may need the following:

Hard hat

Protective footwear with slip-resistant soles

Protective glasses or goggles

Heavy gloves

Wet weather gear

Respirator or filter mask

1000005

Figure 1.2: Safety Equipment

Be aware that exposure to loud noises can cause hearing
impairment or loss. Wear suitable hearing protection devices
such as earmuffs or earplugs to help protect against loud
noises.

1010391

Figure 1.3: Safety Equipment

Provide a first aid kit in case of emergencies.

Keep a properly maintained fire extinguisher on the machine.
Be familiar with its proper use.

Keep young children away from machinery at all times.

Be aware that accidents often happen when the Operator is
tired or in a hurry. Take time to consider safest way.

NEVER

ignore warning signs of fatigue.

SAFETY

Содержание FM100

Страница 1: ...FM100 Float Module Dual Sensor Auto Header Height Control AHHC Kit MD B6211 Installation Instructions 214143 Revision F Original Instruction The Harvesting Specialists...

Страница 2: ...is based on the information available and in effect at the time of printing MacDon Industries Ltd makes no representation or warranty of any kind whether expressed or implied with respect to the info...

Страница 3: ...ation time for this kit is 1 5 hours Conventions The following conventions are used in this document Right and left are determined from the operator s position The front of the float module is the sid...

Страница 4: ...tor is facing down and the sensor arm arrow is facing the combine Added step to ensure the rubber boot is attached to the cable adjuster nut Reordered steps so that the harness gets fully installed be...

Страница 5: ...1 1 2 General Safety 2 Chapter 2 Parts List 5 Chapter 3 Installation Instructions 7 Chapter 4 Troubleshooting 17 4 1 Manually Checking Voltage Range Two Sensor System 17 4 2 Adjusting Voltage Limits...

Страница 6: ......

Страница 7: ...if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation that if not avoided could result in death or serious injury It may also be used to alert agai...

Страница 8: ...e glasses or goggles Heavy gloves Wet weather gear Respirator or filter mask 1000005 Figure 1 2 Safety Equipment Be aware that exposure to loud noises can cause hearing impairment or loss Wear suitabl...

Страница 9: ...machine function and or safety It may also shorten the machine s life To avoid injury or death from unexpected startup of the machine ALWAYS stop the engine and remove the key from the ignition before...

Страница 10: ......

Страница 11: ...OR LINK 2 4 276201 HARNESS LH HEIGHT SENSOR 1 5 276871 HARNESS RH HEIGHT SENSOR 1 6 136410 CLAMP INSULATED 3 8 IN 2 7 136655 FASTENER FIR TREE MT W TIE 4 A 135671 BOLT HEX HD TFL M6 X 1 X 40 8 8 A2L 2...

Страница 12: ......

Страница 13: ...ity The kit is installed with the float module attached to the header 2 Shut down the combine and remove the key from the ignition IMPORTANT Before installing the sensor assemblies make sure you corre...

Страница 14: ...not sold separately 1030467 A B C A Figure 3 3 Installing Sensor Link Bracket 5 Install sensor link bracket A MD 295179 arms into hole B at the top of the float lever with the indented end of the bra...

Страница 15: ...s not twisted and then fully tighten bolt C 1024211 A B Figure 3 5 Right Sensor Assembly 10 Check if jam nuts A are tight against the two ball joints of the right sensor assembly If jam nuts are not s...

Страница 16: ...l the right sensor assembly A onto the rear of the float module frame as shown with bolts B on the assembly slotted into place on the frame Make sure the sensor connector faces down 1030474 A B C Figu...

Страница 17: ...ight Sensor Harness 16 Connect right sensor harness A MD 276871 to the right sensor 17 Route the right sensor harness up inside the frame as shown 1030480 A B C Figure 3 12 Installing Right Sensor Har...

Страница 18: ...xisting clamp that secures the float indicator cable to the frame NOTE Do NOT route the float indicator cable through clamp B 1030542 A B Figure 3 14 Securing Right Sensor Harness 20 Secure the right...

Страница 19: ...igure 3 17 Installing Left Sensor Harness 23 Route left sensor harness A up inside the frame as shown between the frame and hydraulic hoses B 1030534 A B Figure 3 18 FM100 Main Harness P537 24 Near th...

Страница 20: ...the FM100 main harness 1030538 A Figure 3 20 Securing Left Sensor Harness 26 Secure the top end of the left sensor harness to the inside frame using fastener A MD 136655 1030539 A B Figure 3 21 Securi...

Страница 21: ...t the cable tie at plug C45B B on the completion harness b Disconnect connector C45A from plug C45B B c Near the selector valve manifold locate connector C40 A on the FM100 main harness and remove the...

Страница 22: ...or system 29 Before calibrating the AHHC system set float and wing balance A light float will affect AHHC calibration and system performance For instructions refer to the header operator s manual 30 F...

Страница 23: ...e adjusting the sensors verify the sensor arms are properly installed on the sensors Left Sensor A The point on the arm of the sensor should face away from the header The point on the float sensor arm...

Страница 24: ...oth locations NOTE If the header is not on down stops during the next two steps the voltage may go out of range during operation causing a malfunction of the AHHC system 1027026 B A Figure 4 3 Float I...

Страница 25: ...float module side frame Ensure it is at the high voltage limit for the combine NOTE The wiring harness connector must be attached to the sensor Do NOT disconnect it 8 Repeat at the opposite side 10161...

Страница 26: ...ure it is at the low voltage limit for the combine NOTE The wiring harness connector must be attached to the sensor Do NOT disconnect it 11 If the sensor voltage is not within the low and high limits...

Страница 27: ...C D 1 Before adjusting the sensors verify the sensor arms are properly installed on the sensors Left Sensor A The point on the arm of the sensor should face away from the header The point on the float...

Страница 28: ...Kit Left Sensor 4 Loosen sensor mounting nuts A 5 Check that the left sensor is at the correct high voltage limit 6 Rotate sensor B counterclockwise to lower the voltage Rotate sensor clockwise to rai...

Страница 29: ...er the voltage Rotate sensor counterclockwise to raise the voltage 12 Check that the right sensor is at the correct high voltage limit 13 Tighten sensor mounting nuts A 1016102 A Figure 4 11 Float Ind...

Страница 30: ...9230 and 7240 8240 9240 0 5 V 4 5 V 2 5 V Case IH 2588 2577 2 8 V 7 2 V 4 0 V Challenger Gleaner A Massey Ferguson and IDEAL Series 0 5 V 4 5 V 2 5 V CLAAS 500 600 700 Series 0 5 V 4 5 V 2 5 V Gleane...

Страница 31: ......

Страница 32: ...16 891 7313 f 816 891 7323 LLC MacDon Russia Ltd 123317 Moscow Russia 10 Presnenskaya nab Block C Floor 5 Office No 534 Regus Business Centre t 7 495 775 6971 f 7 495 967 7600 MacDon Australia Pty Ltd...