214143
15
Revision F
28. To operate the two-sensor system, connector C40 (A) on the FM100 main harness needs to be connected to the
combine completion harness.
1024347
A
B
Figure 3.22: FM100 Harness C40 Connector and CNH
Completion Harness C45B Plug
1030494
A
B
C
Figure 3.23: FM100 Harness C40 Connector and CNH
Completion Harness C45B Plug
Case New Holland (CNH):
a.
Cut the cable tie at plug C45B (B) on the completion
harness.
b.
Disconnect connector C45A from plug C45B (B).
c.
Near the selector valve manifold, locate connector
C40 (A) on the FM100 main harness, and remove
the cap.
d.
Tuck the sensor harness behind main harness (C) and
then connect plug C45B (B) to connector C40 (A).
1024350
A
B
Figure 3.24: FM100 Harness C40 Connector and CLAAS
Completion Harness C42A Plug
CLAAS:
a.
Disconnect plug C42A from connector C42B (B) on the
completion harness.
b.
Connect plug C42A to connector C40 (A) on the FM100
main harness.