CLOSE BOLLARD, THE TUBE GOES
DOWN
Oil leaks
See point 1
See point 1
Manual unlock is open
See point 3 (O-Ring unlock damaged) See point 3
electric valves are open
Cylinder seal
Replace cylinder seal
Faulty valve seals
Break of the seal valve
Replace the O-Ring in the distributor
6
CLIMB GETS SLOWER
(very viscous oil)
Low temperature
See point 3
See point 3
Exhausted Oil
Replace the oil
Install a resistance
Very high pressure of the bollard
ascent
Too tense pressure valves
Relax the maximum pressure valves
Incorrect supply voltage
See point 3
See point 3
Insuffi cient condenser
7
NOISY PUMP
Presence of air in the circuit (the
bollard doesn’t go up)
See point 1
See point 1
Too viscous oil
Worn oil
Replace the oil
(irregular bollard ascent)
See point 2
See point 2
Wear pump
Excessive inner backlash
Replace oil
Dirty oil
Replace the pump
8
SEAL OIL LEAKS
abrasive substances in the oil
Crack on the seal
Replace the oil and the seal
Worn seals
High oil temperature
Collapsed seal
Refrigerate the oil and replace the
seals
9
EXCESSIVE CONTROL UNIT SUPER
HEATING
(oil too hot)
Intensive use of the control unit
Wear pump
Replace the pump
More movements than expected
Respect the opera ng cycles
Worn oil
Replace the oil
Manual unlock is open
See point 1
See point 1
electric valves are open
See point 1
Irregular set of the limit switch sensors Wrong reading of the limit switch
Set the limit switch in the right
posi on (check the limit switch
sensor and magnet func oning)
Too high pressure
Very ght maximum pressure valves
Set the right pressure by consul ng
“Adjustment of the bollard rising
force”
Oil leaks with loss of pressure
See point 1
See point 1
High external temperature
See point 3
See point 3
Wrongly regulated valves
Oil overhea ng
Respect the func on temperature
Low regulated valves
Ask the constructor
10
THE BOLLARD DOESN’T
COMPLETELY GO UP
(incorrect regula ons)
Low oil level in the tank
See point 1
See point 1
Irregular set of the limit switch sensors See point 10
See point 10
Insuffi cient condenser
See point 3
See point 3
Too high pressure
See point 10
See point 10
incorrect ming
Adjust me on the brain
11
HIGH WATER LEVEL OF THE
FORMWORK
Obstructed sewer
Foliage / debris slow down the waste
water
Do maintenance (clean the well)
non-draining soil
The soil absorbs li le water
Build a well or a sewer with pump to
draw waste water
Request an IP67 hydraulic control
unit
12
LIGHTING HEAD NOT WORKING
Faulty or wrong regulated limit
switches
Wrong cable installa on
Rewiring respec ng the polarity of
the cables
Wrong connec ons
Faulty cables
Cables replacement
Socket not connected
Connect the plug into the head
socket
See point 14
See point 14
Faulty fuses
Check fuses
Replace fuses
Содержание C275A
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 37: ...info mac srl it 37 00_Manutenzione 05 200203 GBR...
Страница 38: ...www mac srl it 38 00_Manutenzione 05 200203 GBR...
Страница 39: ...info mac srl it 39 00_Manutenzione 05 200203 GBR...
Страница 40: ...www mac srl it 40 00_Manutenzione 05 200203 GBR...