WF G
LOBAL
A
DMINISTRATOR
S
ECTION
C
HAPTER
1: S
YSTEM
SCREEN
M86 S
ECURITY
U
SER
G
UIDE
189
Configuration
Set up Blocking Criteria
1. At
Reset the X-Strike count upon authentication
, “Off”
is selected by default. To have all strikes reset before an
end user is authenticated, click “On”.
2. Enter the
Maximum Strikes Before “Locking” the
Workstation
. This is the number of attempts a user can
make to access an unacceptable site before that user is
prevented from using the Internet. The default is
5
, and
the maximum limit is 1000.
3. Enter the
Time Span in Minutes to Track the No. of
Strikes Within Category
. This is the amount of time
between a given user's first strike and the strike that will
lock out that user from his/her Internet access. The
default setting is
5
, and the maximum limit is 1440
minutes (24 hours).
4. Enter the number of seconds for the
Flood Tolerance
Delay
, which is the maximum amount of time that will
elapse before a user who accesses the same inappro-
priate URL will receive another strike. The default setting
and the maximum limit is
4
seconds.
5.
Specify the “Locked” Life Time (Measured in
Minutes)
, which is the number of minutes a user's work-
station will be locked. Choose either “Unlimited”, or
“Defined”.
If “Defined” is selected, enter the number of minutes in
the text box. The default setting is
5.
6.
Specify a Redirect URL
to be used when the end user is
locked out from his/her workstation. By default, “Default
"Alternate" Locked Block Page” is selected, indicating
that the standard lock out block page will display.
Содержание M86 Threat Analysis Reporter
Страница 1: ...M86 Web Filtering and Reporting Suite USER GUIDE Software Version 4 2 00 Document Version 10 10 11...
Страница 28: ...CONTENTS xxviii M86 SECURITY USER GUIDE INDEX 887...
Страница 518: ...WEB FILTER APPENDICES SECTION APPENDIX D 490 M86 SECURITY USER GUIDE Fig D 20 Mobile Client Package Contents page...
Страница 938: ...INDEX 910 M86 SECURITY USER GUIDE...