Page 32
3.7.2
Return to Meters
Hilo will revert to the Meters screen after some period of inactivity. The default period is 5 minutes. This is where you can change that
delay time.
•
Shows the current Menu Delay
•
This sets the time that any menu, selection page, pop up menu or status page will
stay active before the screen defaults back to the selected Meter page.
The only
menu page that does not “time out” is the Output Mix Routing Page.
•
Pushing the button engages a horizontal fader that lets you set the delay to 15
seconds, 30 seconds, 1 minute, 2 minutes, 5 minutes, or Never.
•
You may use your finger on the fader to set the delay time.
•
You may also use the Rotary Control to set the delay time.
3.7.3
Show/Hide Settings
This button allows selection of what parameters, if any, will appear on the Meter pages.
The choices are Sample Rate, Sync Source, and Scene Recall. When Scene Recall is
selected, pressing the button will reveal any scenes stored in Hilo’s memory. Sample Rate
and Sync Source will only display the current values for those parameters if there is an
active USB connection to the computer. If there is not an active USB connection to the
computer, then these settings can be changed by pressing the appropriate button.
3.7.4
Analog VU Reference
You can calibrate the Analog meters to set the 0 VU level.
Using the fader on-screen or the Rotary Knob, the 0 VU mark on the
meters can be calibrated between -3dBFS and -24dBFS.
3.7.5
Calibrate Touchscreen
The LCD Touchscreen has a grid that detects when you touch it to select or change settings. If you find that the touch response gets
slow or does not always engage properly, you may need to recalibrate the touch screen.
•
Push the Calibrate Touchscreen button.
•
The screen will go black and give you instructions for
recalibrating the screen.
Simply follow the instructions and the previous screen will come up
when done. Be sure to touch directly in the center of the target to
give the most accurate touchscreen calibration.
With a touch screen it is easy to engage the wrong function by mistake. This screen allows you to back out of this command if you
wish.
There are times when calibrating the touchscreen is necessary for optimum performance. However if this setting was selected
unintentionally, now you can overrule the request and return to the Display Menu page.