Section 7: Commissioning
P a g e | 22
7.2.3
External
Easyzon D
System Device Checks
Continue with performing the following steps:
6.
At this point test the function of any external
alarm/
inhibit input signals that may have been
connected to
the
Easyzon D
control panel, for
example chemical
suction lance switches used
to indicate drum/tank
empty status.
7.
Check the status and function of any external
alarm
output devices connected to the
Easyzon D
for
example
an alarm beacon, remote PLC status.
8.
Check the status and function of any Modbus
device
that may be connected to the optional
Easyzon D
external communications panel.
✓
External device checks complete.
7.2.4
Water Purge Kit
The water purge kit connects to the inlet of the inline
strainers on the
Easyzon D.
It is used during
commissioning and servicing procedures to purge the
system with water.
Description
1 Suction strainer
2 6mmOD x 4mmID tubes