Section 3: Technical Data
P a g e |
8
3.3 Connections
3.3.1
Hydraulic
3.3.2
Electrical
3.4 Electrical Specification
3.5 Consumption Data
3.6 Output Data
3.7 Precursor Chemical Specification
In accordance with the Biocidal Products Regulation
(BPR), Regulation (EU) 528/2012, the member states of
the European Union may only use precursors for the
generation of biocidal active substances produced “in
situ” which are authorised under Article 95 of the
regulation. These precursors must be sourced from a
manufacturer or supplier listed in accordance with Article
95 of the BPR. Please ask your supplier to confirm
conformity with the biocide ordinance (certificate or
Letter of Access).
Note:
•
Output data is determined by the precursor
quality
&
concentration.
Tolerance
is
permissible up to ±10%, however this may affect
the performance specified.
3.8 Operating Conditions and Limits
Connection
Description
Cold water dilution
½” BSPf
Precursor chemical
4mmID x 6mmOD tube
compression
Connection
Description
Mains power input
M20 cable gland
Signal input/output
M12/16 cable gland
Chemical empty switch
input
M12 connector - A code
Description [all models]
Power supply
1Ø, 100-240VAC
Power rating
20W (excluding auxiliary
equipment)
Aux output
1Ø, 100-240VAC, 5A
Enclosure class of
electronic panel
IP64
General system
protection class
IP64
Model:
Low strength
High strength
100
200
250
500
Nominal water
consumption (l/h)
45
90
120
240
Precursor
consumption ratio
1:1
Precursor
consumption, each
(L/h)
2.5
5
2.5
5
Model:
Low strength
High strength
100
200
250
500
Generation capacity
(g/h ClO
2
)
100
200
250
500
Generation capacity
(L/h)
50
100
125
250
Solution concentration
(mg/L ClO
2
)
2000
Product tank volume
(L)
80
Model:
100
200
250
500
9.0% HCl (EN939)
✓
✓
7.5% NaClO
2
(EN938)
✓
✓
≈
15.0% HCl (EN939)
✓
✓
≈
14.0% NaClO
2
(EN938)
✓
✓
Model:
100
250
200
500
Water supply inlet
pressure (MPa)
0.2-1.6 (Min-Max)
Reduced pressure
value (MPa)
0.05
– 0.1
Dilution water
temperature (
o
C)
5-20
Precursor temperature
(
o
C)
10-35
Ambient temperature
(
o
C)
5-35
Dilution Water Quality
Potable
Содержание Easyzon D 100