S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

Vive

HMS-0, HMS-1, HMS-2

Wireless Hub

3691044-04g   5   03.23.21

How to Build a Model Number

Example

 

H M S   –   1   –   F M

Frequency

  M = 868.125 –868.475 MHz

Type

  0 =  Starter Vive hub without BACnet

R

 limited to  

75 devices.

  1 = Vive hub without BACnet

R

  2 = Premium Vive hub with BACnet

R

Mounting

  FM = Flush-Mount (non-metal ceiling tiles or drywall)

Available Vive Hub Model Numbers (includes power 
supply and mounting adapter)

  HMS-0-FM -  Starter Vive hub, flush-mount adapter and 

power supply

  HMS-1-FM -  Vive hub, flush-mount adapter and  

power supply

  HMS-2-FM -  Premium Vive hub, flush-mount adapter  

and power supply

  HMS-UPDATE -  Software upgrade license to add 

BACnet

R

 to HMS-0 and HMS-1 hubs 

  HMS-DEVICES -  Software upgrade license expands 

device limit to 700 devices for  
HMS-0 hubs

Frequency

Mounting

Type

Replacement Part Model Numbers

  PS-M-20W-240 

 Vive hub external power supply

  H-MOUNT-FM  

 Flush-mount installation adapter

  H-MOUNT-SM 

 Surface-mount installation adapter

5

Содержание Vive HMS-0

Страница 1: ...multi color LED provides feedback on what mode the hub is in Connects directly to any smartphone tablet or computer using built in Wi Fi 2 4 GHz 802 11b g using WPA2 Security Ethernet 10 100 Mbps con...

Страница 2: ...holidays Allows scheduling events on specific day of the year Provides calculated energy data for PowPak modules Create and edit areas Tune area light levels by trimming the high end and low end outp...

Страница 3: ...pp Maximum of 50 scenes are supported Requires Vive hub software 01 13 or higher Programmable CCI The second contact closure input CCI 2 can be programmed to activate a scene Scene activation o Set a...

Страница 4: ...re Input Terminals First contact closure input CCI 1 is to be used for initiating load shed only The second contact closure input CCI 2 may be programmed to activate a scene If activating a scene a de...

Страница 5: ...Hub Model Numbers includes power supply and mounting adapter HMS 0 FM Starter Vive hub flush mount adapter and power supply HMS 1 FM Vive hub flush mount adapter and power supply HMS 2 FM Premium Viv...

Страница 6: ...re shown as mm Surface mount Adapter Details Knockouts for conduit Vive Hub Top View Side View 173 135 71 38 Flush mount Adapter Top View Side View 165 79 Surface mount Adapter Top View Side View 122...

Страница 7: ...b Note Vive hubs should be mounted greater than 3 m from a Wi Fi router or access point 30 m 30 m Private Office PowPak Dimming Module Conference Room PowPak Dimming Module Open Office PowPak Relay Mo...

Страница 8: ...tyle junction box Supplied US style junction box Vive hub Flush mount adapter Vive Hub CCI1 COM 24 V COM CCI2 Red Blue Ethernet 10 100 LAN 24 V 220 240 V Ceiling Power supply Vive hub Surface mount ad...

Страница 9: ...rest technologies The Vive hub can be deployed in one of two ways Dedicated Lutron Network Connected to the corporate IT network via Ethernet The Vive hub must be connected via Ethernet to access cer...

Страница 10: ...ed to discover the Vive hub when mDNS is not available 5353 UDP Ethernet Used to discover the Vive hub via mDNS Configurable TCP Ethernet Used for OpenADRR Specified by utility company Inbound 443 TCP...

Страница 11: ...ommunication link Inter Hub Link Wiring Security 1 continued Link segment 100 m Ports Used Traffic Port Type Connection Description Outbound 47808 configurable UDP Ethernet Used for BACnet integration...

Страница 12: ...LB P LRF4 OHLB P LRF4 OWLB P In Line Phase Control Dimmers2 RMMS 250 NE The Lutron logo Lutron Lutron Clear Connect Pico PowPak Radio Powr Savr Vive Vue and Vive are trademarks or registered trademark...

Отзывы: