S P E C I F I C AT I O N S U B M I T TA L
Page
Job Name:
Job Number:
Model Numbers:
Vive
HMS-0, HMS-1, HMS-2
Wireless Hub
3691044-04g 2 03.23.21
Features
(continued)
• Daylighting-to-Low-End or Daylighting-to-Off - The
Vive system will allow the user to select either
daylighting-to-low-end or daylight-to-off on an area
by area basis.
• Customer Supplied Security Certificates
– Provides customers the abiltiy to load their own
authentication certificates for their specific domain.
– Provides customers using the Vive hub application
to use secure browser communications without
receiving any authentication warnings due to the
self-signed certificates that are shipped with the
hubs.
• Timeclock Occupancy Sensor Settings Changes
– Allows timeclock events to change the behavior
of occupancy settings based on time of day.
For example, change the unoccupied level of
corridors / hallways from 25% during the day,
and off at night. The following settings can be
changed:
– Occupied Level – The level the lights go to when
occupied. Changes are not applied immediately
to currently occupied spaces, but will change the
next time the space goes occupied to minimize
distraction.
– Unoccupied Level – The level the lights go to when
unoccupied. Changes are applied immediately to
spaces not currently occupied.
– Enable / Disable Occupancy – Change whether
devices will respond to the occupancy sensor.
• 365-day schedulable timeclock with exceptions for
holidays.
– Allows scheduling events 10 years in advance.
– Set recurring events with exceptions on holidays.
– Allows scheduling events on specific day of the
year.
• Provides calculated energy data for
PowPak modules.
• Create and edit areas.
• Tune area light levels by trimming the high-end and
low-end output.
• Adjust occupancy settings. Create occupancy
groups.
• User can choose to extend the RF range of up to 15
of the total Pico remote controls per Vive hub. These
remotes will be able to control any devices within the
22 m range.
• RF range of occupancy sensors can be extended
for up to 14 areas per Vive hub. In a range-extended
area, an occupancy sensor can control any device
in that area, regardless of distance between sensor
and device. Requires Vive hub software 01.09
or higher.
• Configurable Fade Time
– Up to 90 minutes for timeclock events and scenes.
o
Limited to 90 seconds for RMMS-DAL32-SZ and
RMMS-DAL4-SZ devices.
– Up to 90 seconds for Pico remote control
programming.
o
Fade time may differ between buttons on the
same Pico remote control.
o
Single fade time applies to all programming for
a button.
• Automatic Demand Response / Load Shed
– Load Shedding will physically dim the lights to a
programmable level.
– OpenADR
R
2.0b compliant (requires Vive hub
software 01.09 or higher).
– May be enabled (or disabled) via any of the
following methods:
o
The first contact closure input (CC1)
o
BACnet
R
integration
o
OpenADR
R
integration
– OpenADR
R
requires access to utility companies
over the Internet, so the hub must be connected
via Ethernet to use OpenADR
R
.
• Alerts
– View run-time issues which may prevent devices
from operating as expected, such as low batteries
or missing devices.
• API Integration
– To integrate with third-party devices, systems,
and software, RESTful APIs are available over
the Ethernet.
2