background image

2.4 Modes in detail

2.4.1 Splitter mode (1) A:     B: 

The LumiSplit now runs in A / B splitter mode. This is the default 
mode.

2.4.2 Backup mode (1) A:     B: 

Zone A becomes the main input, Zone B the backup input. In 
the unlikely event of DMX loss on Zone A, the splitter will switch 
automatically to zone B.
This mode can be used to create a backup situation for two 
network converters. In case of failure of the first device, the 
LumiSplit will automatically switch to the other device. 
When the DMX signal is lost on input A, the A LED turns red, and all 
output LEDs turn red. This provides the user with a clear indication 
that the LumiSplit has switched to the secondary input. 
When the DMX signal is back available on input A, the A LED will 
turn blue again but unless auto recovery has been enabled, the 
LumiSplit will NOT switch back to input A.
When the LumiSplit has recovered to Input A, all output LEDs will 
turn Blue/Cyan again.
When the DMX signal on input B is NOT present both LEDs turn 
red.

To give back control to input A, you need to press the A input 
button or use the control panel through LumiNet Monitor.

Alternatively, from firmware version 6 onwards, it is possible to 
enable Auto recovery via RDM. (see paragraph 3.8)

2.4.2 HTP merging mode (3)  A:     B: 

The LumiSplit will merge the two DMX inputs according to the 
Highest Takes Precedence policy. RDM communication with 
connected endpoints is no longer active.

2.4.4 LTP merging mode (4)  A:     B: 

The LumiSplit will merge the two DMX inputs according to the 
Latest Takes Precedence policy.
RDM communication with connected endpoints is no longer 
active.

2.4.5 Regeneration Zone A (5)  A:     B: 

The LumiSplit will re-generate the incoming DMX signal on input 
A with some new parameters. These parameters can be selected 
through LumiNet monitor. (for more information, see 3.7.4)
RDM communication with connected endpoints is no longer 
active.

2.4.6 Regeneration Zone B (6)  A:    B: 

The LumiSplit will re-generate the incoming DMX signal on input 
B with some new parameters. These parameters can be selected 
through LumiNet monitor. (for more information, see 3.7.4)
RDM communication with connected endpoints is no longer 
active.

2.4.7 Regeneration Zone A + B (7)  A:     B: 

This mode allows you to quickly select regeneration mode for both 
inputs. The timing for each input will be set as described above.
RDM communication with connected end points is no longer 
active on both zones.

2.4.8 Dark Mode (8) 

Dark mode set the brightness of all LEDs to a low value. This avoids 
the LumiSplit generating too much light from its LEDs, where 
darkness is a must have. Once you press one of the buttons on the 
front panel, the brightness will go back to full for a few seconds. 
Select the dark mode again from the selection menu to disable it. 
Dark mode can be set from LumiNet Monitor as well.

2.4.9 User Preset 1 (9) and 2 (10)

Two user Presets can be stored on outlet 9 & 10. This allows you to 
easily recall your favourite configuration or alternate between two 
configurations for different applications. To record a preset, and 
once in the selection mode, simply hold one of the two buttons 
to store your configuration. Once the output LED start blinking on 
its own, you can release the button. To recall the profile, once in 
selection mode, press once on the output button to reload the 
preset. These actions can be performed through LumiNet Monitor 
as well.

 

2.5 Front Panel Lock

For reliability reasons you can lock the front panel. In this way, no-
body can accidentally change the settings of the splitter during a 
live event for example. To lock and un-lock the front panel, press 
and hold the input A button for 4 seconds. Once the power LED 
indicator blinks orange, release the button and the power LED in-
dicator will turn orange. The front panel is now successfully locked. 
Execute the same procedure to unlock the front panel again.
The front panel can be locked/unlocked from LumiNet Monitor 
as well.

2.6 Factory Reset

Sometimes it can come in handy to reset the entire device. To do 
that, press and hold the input A button for 10 seconds. Once the 
power LED indicator blinks red, release the button. This will reset 
all settings to default. Please keep in mind that also all user presets 
will be deleted after this procedure.
The LumiSplit can be remotely reset from LumiNet Monitor as well.

8

2 LUMISPLIT FEATURES AND MODE SELECTION / 

2.4 MODES IN DETAIL / 2.5 FRONT PANEL LOCK / 2.6 FACTORY RESET

Содержание LumiSplit 2.10

Страница 1: ...USER MANUAL LUMISPLIT PRODUCT FAMILY LumiSplit 2 10 THANKS FOR CHOOSING LUMINEX Description User Manual LumiSplit 2 10 REVISION 20200820 REV 6 0 0...

Страница 2: ...2...

Страница 3: ...e Selection 7 2 4 Modes in detail 8 2 5 Front Panel Lock 8 2 6 Factory Reset 8 3 THE NEW RDM EXPERIENCE 9 3 1 Discovery 9 3 2 Identify a LumiSplit 9 3 3 Lock Unlock the Front Panel 10 3 4 Dark Mode 10...

Страница 4: ...local dealer if you don t have a suitable power cable on hand The device will automatically switch on To shut it down after use just un plug the power cable again After connecting the power cable corr...

Страница 5: ...he selected mode D OUTPUT BUTTON Output selector enable disable RDM filtering per output E OUTPUT LED Indicates the output status and the selected mode 1 3 2 Rear Panel F POWER 1x Neutrik powerCONTRUE...

Страница 6: ...ed blink Factory Reset Blue DMX fail mode or Startup mode configured PORT LED STATUS DESCRIPTION Input A front panel Blue DMX RDM Cyan DMX Only White blink RDM activity Input B front panel Red DMX RDM...

Страница 7: ...enable or disable RDM filtering per zone A B The input LED indicator colour will change together with all associated output LED indicators RDM FILTERING PER OUTPUT Press the input button together with...

Страница 8: ...ication with connected endpoints is no longer active 2 4 7 Regeneration Zone A B 7 A B This mode allows you to quickly select regeneration mode for both inputs The timing for each input will be set as...

Страница 9: ...LumiNet Monitor 2 1 6 or higher and LumiSplit firmware v5 or higher are necessary to take full benefit of all the features listed below 3 1 Discovery Wrong text Should be The LumiSplit 2 10 comes wit...

Страница 10: ...ers and select display level Here you can set the brightness either to low or full There is no intermediate value available for the brightness of the LEDs 3 5 Mode Selection Youcanremotelyselectoneoft...

Страница 11: ...nnected to right click on one of the responders of the LumiSplit 2 10 and se lect Control In the control panel click on the endpoint tab If RDM devices are connected to the splitter they will appear o...

Страница 12: ...ify a port If needed you can identify a port To do so tick the corresponding Identify check box and the LED of the selected port will blink white This can come in handy when you need to indicate the p...

Страница 13: ...go to the Backup Recover main option and click on the Set button All output LEDs will turn blue again 3 8 2 Backup Auto Recovery The LumiSplit firmware version 6 onwards offers the option to automati...

Страница 14: ...esending the last frame is the same as set for the regeneration mode default 36 FPS with a break time of 184 s Send snapshot makes it possible to send out the captured snap shot as lighting state with...

Страница 15: ...ill follow the incoming DMX again LEVEL The level is a value that acts as a master level on the cap tured preset LumiSplit only supports 255 full as level 3 12 Messages The LumiSplit can send messages...

Страница 16: ...is a knowledge base available online that gets updated on a regular basis at https support luminex be If you need to ask our team for more help or you need to return a de vice to Luminex for diagnosti...

Страница 17: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 17...

Страница 18: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Отзывы: