After the device has been powered-up correctly, you can start 
changing the different operating modes and port features through 
the front panel or via RDM. To change the settings by using the 
front panel, follow these instructions. 

Through the front panel, you can connect 2 inputs (A and B) and 
10 outputs (1 to 10). Each output has a LED indicator and a push 
button. These are used to change and display the port status. The 
input buttons are used to change the operating mode of the split-
ter.

2.1 Zone selection per port

By default, every output is linked to input / zone A. To toggle be-
tween zone A and B, 

shortly press the A / B button

 next to the 

specific output. The output LED indicator colour will change ac-
cordingly. Press the button again to toggle between A and B once 
more.

2.2 RDM Filtering

The LumiSplit supports RDM filtering to prevent lighting fixtures 
from being flooded by undesired RDM packets. You can enable or 
disable RDM filtering per input (zone A / B) or per output.

 RDM FILTERING PER INPUT:

Press the input button shortly

 to enable or disable RDM filtering 

per zone (A / B). The input LED indicator colour will change, 
together with all associated output LED indicators.

 RDM FILTERING PER OUTPUT:

Press the input button together with the desired output 
button (shortly) 

to enable or disable RDM filtering on that output. 

The output LED indicator colour will change accordingly.

2.3 Mode Selection

The LumiSplit 2.10 has different operating modes. To change the 
mode, 

hold both input buttons (A and B)

 together for 2 seconds. 

The LEDs from both ports will start blinking blue. Then 

release the 

two buttons and press the desired output button

 to select the 

mode. Each output button represents another mode.

Step 1: hold the A + B button until the port LEDs change colour.

Step 2: Press the output button corresponding to the desired 
mode. A list of the different modes can be found on the label on 
the rear of the device.

BUTTON

COLOUR

MODE SELECTION

Output 1

Blue

Splitter

Output 2

Blue

Backup

Output 3

Blue

HTP Merging

Output 4

Blue

LTP Merging

Output 5

Blue

Regeneration Zone A

Output 6

Blue

Regeneration Zone B

Output 7

Blue

Regeneration Zone A + B

Output 8

Green

Dark Mode

Output 9

Orange

User Preset 1

Output 10

Orange

User Preset 2

7

2. LUMISPLIT FEATURES AND MODE SELECTION

Содержание LumiSplit 2.10

Страница 1: ...USER MANUAL LUMISPLIT PRODUCT FAMILY LumiSplit 2 10 THANKS FOR CHOOSING LUMINEX Description User Manual LumiSplit 2 10 REVISION 20200820 REV 6 0 0...

Страница 2: ...2...

Страница 3: ...e Selection 7 2 4 Modes in detail 8 2 5 Front Panel Lock 8 2 6 Factory Reset 8 3 THE NEW RDM EXPERIENCE 9 3 1 Discovery 9 3 2 Identify a LumiSplit 9 3 3 Lock Unlock the Front Panel 10 3 4 Dark Mode 10...

Страница 4: ...local dealer if you don t have a suitable power cable on hand The device will automatically switch on To shut it down after use just un plug the power cable again After connecting the power cable corr...

Страница 5: ...he selected mode D OUTPUT BUTTON Output selector enable disable RDM filtering per output E OUTPUT LED Indicates the output status and the selected mode 1 3 2 Rear Panel F POWER 1x Neutrik powerCONTRUE...

Страница 6: ...ed blink Factory Reset Blue DMX fail mode or Startup mode configured PORT LED STATUS DESCRIPTION Input A front panel Blue DMX RDM Cyan DMX Only White blink RDM activity Input B front panel Red DMX RDM...

Страница 7: ...enable or disable RDM filtering per zone A B The input LED indicator colour will change together with all associated output LED indicators RDM FILTERING PER OUTPUT Press the input button together with...

Страница 8: ...ication with connected endpoints is no longer active 2 4 7 Regeneration Zone A B 7 A B This mode allows you to quickly select regeneration mode for both inputs The timing for each input will be set as...

Страница 9: ...LumiNet Monitor 2 1 6 or higher and LumiSplit firmware v5 or higher are necessary to take full benefit of all the features listed below 3 1 Discovery Wrong text Should be The LumiSplit 2 10 comes wit...

Страница 10: ...ers and select display level Here you can set the brightness either to low or full There is no intermediate value available for the brightness of the LEDs 3 5 Mode Selection Youcanremotelyselectoneoft...

Страница 11: ...nnected to right click on one of the responders of the LumiSplit 2 10 and se lect Control In the control panel click on the endpoint tab If RDM devices are connected to the splitter they will appear o...

Страница 12: ...ify a port If needed you can identify a port To do so tick the corresponding Identify check box and the LED of the selected port will blink white This can come in handy when you need to indicate the p...

Страница 13: ...go to the Backup Recover main option and click on the Set button All output LEDs will turn blue again 3 8 2 Backup Auto Recovery The LumiSplit firmware version 6 onwards offers the option to automati...

Страница 14: ...esending the last frame is the same as set for the regeneration mode default 36 FPS with a break time of 184 s Send snapshot makes it possible to send out the captured snap shot as lighting state with...

Страница 15: ...ill follow the incoming DMX again LEVEL The level is a value that acts as a master level on the cap tured preset LumiSplit only supports 255 full as level 3 12 Messages The LumiSplit can send messages...

Страница 16: ...is a knowledge base available online that gets updated on a regular basis at https support luminex be If you need to ask our team for more help or you need to return a de vice to Luminex for diagnosti...

Страница 17: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 17...

Страница 18: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Отзывы: