3.9 Snapshot

From firmware version 6 onwards the LumiSplit offers the option to 
record a DMX snapshot per input. This snapshot can later be used for 
the DMX fail mode or Startup mode.
To use this new feature, the user will need LumiNet Monitor v2.3.2 or 
higher.

3.9.1 Capture Snapshot

To capture the snapshot, an active lighting state needs to be present.
To capture the snapshot please perform the following steps:

 

ƒ

Open LumiNet Monitor and locate the responder of the desired  

  device(s) in the RDM devices list.

 

ƒ

Select the desired responder(s) and right click.

 

ƒ

From the pop-up window, choose Capture Snapshot  

  (option 3 from the bottom)

The snapshot has now successfully been made.

3.10 DMX Fail Mode

In DMX Fail mode, the LumiSplit offers 3 options as output in the un-
likely event that something happens to the DMX input signal.
The three options available are:

 

ƒ

Do Nothing (default), There will be NO DMX signal forwarded to 
the outputs of the respected input, until valid DMX signal arrives 
at  the input.

 

ƒ

Resend last frame, will keep repeating the last received DMX frame  
on all outputs of the respective input (zone). As soon as the DMX  
input receives valid DMX again, the output will follow that new in-
put again. The frame rate used for resending the last frame is the 
same as set for the regeneration mode (default: 36 FPS with a break 
time of 184 μs). 

 

ƒ

Send snapshot, makes it possible to send out the captured snap 
shot as lighting state with defined timings. In this way the snap-
shot will be send to all concerned outputs until valid DMX input 
signal is received or until the hold time expires. When a valid DMX 
input signal is received again, the outputs will follow the  input data. 
 
When the DMX Fail mode is active all the output port LEDs will blink 
slowly in sync.

3.10.1 Configure DMX Fail mode

To set the DMX Fail mode, use the following steps:

 

ƒ

Select the desired responder in the RDM devices list.

 

ƒ

Right click and select DMX Fail mode.

 

ƒ

Choose the option you want to use.

3.11 DMX Startup Mode

With the DMX Startup mode , you can define the behaviour of the Lu-
miSplit at Startup for each input. If no DMX signal is present, you may 
choose the following 2 options:

 

ƒ

Do Nothing (default), There will be NO DMX signal forwarded to 
the outputs of the respected input, until valid DMX signal arrives 
at the input.

 

ƒ

Send snapshot, makes it possible to send out the captured snap-
shot as lighting state with defined timings. In this way the snapshot 
will be send to all concerned outputs until valid DMX input signal is 
received or until the hold time expires. When valid DMX input signal 
is received, the outputs will follow the input data.

14

3 | THE NEW RDM EXPERIENCE / 

3.9 SNAPSHOT / 3.10 DMX FAIL MODE / 3.11 DMX STARTUP MODE

Содержание LumiSplit 2.10

Страница 1: ...USER MANUAL LUMISPLIT PRODUCT FAMILY LumiSplit 2 10 THANKS FOR CHOOSING LUMINEX Description User Manual LumiSplit 2 10 REVISION 20200820 REV 6 0 0...

Страница 2: ...2...

Страница 3: ...e Selection 7 2 4 Modes in detail 8 2 5 Front Panel Lock 8 2 6 Factory Reset 8 3 THE NEW RDM EXPERIENCE 9 3 1 Discovery 9 3 2 Identify a LumiSplit 9 3 3 Lock Unlock the Front Panel 10 3 4 Dark Mode 10...

Страница 4: ...local dealer if you don t have a suitable power cable on hand The device will automatically switch on To shut it down after use just un plug the power cable again After connecting the power cable corr...

Страница 5: ...he selected mode D OUTPUT BUTTON Output selector enable disable RDM filtering per output E OUTPUT LED Indicates the output status and the selected mode 1 3 2 Rear Panel F POWER 1x Neutrik powerCONTRUE...

Страница 6: ...ed blink Factory Reset Blue DMX fail mode or Startup mode configured PORT LED STATUS DESCRIPTION Input A front panel Blue DMX RDM Cyan DMX Only White blink RDM activity Input B front panel Red DMX RDM...

Страница 7: ...enable or disable RDM filtering per zone A B The input LED indicator colour will change together with all associated output LED indicators RDM FILTERING PER OUTPUT Press the input button together with...

Страница 8: ...ication with connected endpoints is no longer active 2 4 7 Regeneration Zone A B 7 A B This mode allows you to quickly select regeneration mode for both inputs The timing for each input will be set as...

Страница 9: ...LumiNet Monitor 2 1 6 or higher and LumiSplit firmware v5 or higher are necessary to take full benefit of all the features listed below 3 1 Discovery Wrong text Should be The LumiSplit 2 10 comes wit...

Страница 10: ...ers and select display level Here you can set the brightness either to low or full There is no intermediate value available for the brightness of the LEDs 3 5 Mode Selection Youcanremotelyselectoneoft...

Страница 11: ...nnected to right click on one of the responders of the LumiSplit 2 10 and se lect Control In the control panel click on the endpoint tab If RDM devices are connected to the splitter they will appear o...

Страница 12: ...ify a port If needed you can identify a port To do so tick the corresponding Identify check box and the LED of the selected port will blink white This can come in handy when you need to indicate the p...

Страница 13: ...go to the Backup Recover main option and click on the Set button All output LEDs will turn blue again 3 8 2 Backup Auto Recovery The LumiSplit firmware version 6 onwards offers the option to automati...

Страница 14: ...esending the last frame is the same as set for the regeneration mode default 36 FPS with a break time of 184 s Send snapshot makes it possible to send out the captured snap shot as lighting state with...

Страница 15: ...ill follow the incoming DMX again LEVEL The level is a value that acts as a master level on the cap tured preset LumiSplit only supports 255 full as level 3 12 Messages The LumiSplit can send messages...

Страница 16: ...is a knowledge base available online that gets updated on a regular basis at https support luminex be If you need to ask our team for more help or you need to return a de vice to Luminex for diagnosti...

Страница 17: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 17...

Страница 18: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Отзывы: