background image

2.5 Connecting to the web interface

 

The default GigaCore IP address is displayed at the rear of the  

 

unit. Set your computer with a compliant IP address (do not  

 

use the same IP address!).

 

Connect your computer to the GigaCore with a network cable.

 

Launch your favourite web browser.

 

Type the IP address of the switch in the address fi eld followed  

 by 

enter.

 

PLEASE KEEP IN MIND THE WEB INTERFACE OF A SWITCH 

CAN ONLY BE REACHED THROUGH A PORT ASSIGNED IN THE 

MANAGEMENT GROUP (FROM THE SWITCH YOU’RE CONNECTED 

TO, OR FROM ANOTHER SWITCH THROUGH AN ISL PORT). YOU 

NEED AT LEAST ONE PORT ASSIGNED TO THE MANAGEMENT 

GROUP IN YOUR ENTIRE NETWORK TO REACH THE WEB INTER-

FACE OF ALL YOUR GIGACORE SWITCHES

FACTORY DEFAULT ALL PORTS ARE ASSIGNED TO THE MANAGE-

MENT GROUP.

2.6 Reset

Sometimes it can come in handy to reset the device. To do this, 

press and hold the mode button for 5 seconds. Once the four sta-

tus LEDs blink red, release the button. This will reset all settings to 

default. The user profi les will be preserved though.

For more detailed information on how to reset the device and 

what reset options are available please check chapter 4 of this 

manual.

2.4 LED indicators:

The LED indicators of the GigaCore 26i and GigaCore 26i with PoE 

show the following statuses:

SWITCH LED

COLOUR

DESCRIPTION

OK (General status LED)

Green

All OK

Green blink

Unit is writing to the fl ash. 
Do not disconnect power

Orange

Temperature warning

Red blink

Temperature or Fan error

Red/Green 

blink

The unit is fl ashing new 

fi rmware. Do not discon-

nect power

PoE LED (GigaCore 26i 

with PoE only)

Green

Internal PoE supply OK 

and RPSU connected. PoE 

functionality OK

Red blink

PoE supply or PoE 

functionality error

Orange

Internal PoE supply OK (no 

RPSU connected)

RLinkX LED

Green

RLinkX is active

Red blink

OOS occurred on the 

switch

Power LED

Green

Internal power supply OK 

and RPSU connected

Orange

Internal power supply OK 

(no RPSU connected)

Red blink

Power error

PORT LED

STATUS

DESCRIPTION

Link

Off No 

Link

Green

Gigabit connection

Orange

10/100 Mbps connection

Blink

Activity

With the use of the mode button, the user can get all the neces-

sary information immediately. Press the mode button to browse 

through the diff erent states.

STATE

MODE LED

PORT MODE LED

DESCRIPTION

Groups

White

Group Colour

The LED colour indicates the group assignation of the port

RLinkX

Blue

Blue

Indicates a redundant port

Red blink

OOS occurred on that particular port

MultiLinkX

Magenta

Magenta

MultiLinkX is enabled on this port

White

MultiLinkX is active on this port

PoE

Yellow

Yellow

PoE is activated on this port

Orange

Port is sourcing PoE to a device

Red

Error with PoE

Dark Mode

Off Off 

All port LEDs are switched off . Switch status LEDs remain available. 

8

2 | INSTALLATION / 

2.4 LED INDICATORS / 2.5 CONNECTION WEB INTERFACE / 2.6 RESET

Содержание GigaCore 26i with PoE

Страница 1: ...USER MANUAL GIGACORE PRODUCT FAMILY GigaCore 26i Description User Manual GigaCore 26i REVISION 20220623 REV 2 8 7 THANKS FOR CHOOSING LUMINEX...

Страница 2: ...PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONEL AVERTISSEMENT AUCUNE PI CE CONTENUE L INT RIEUR NE PEUT ETRE R PAR E PAR L UTILISATEUR VEUILLEZ CONFIER TOUTE R PARATION UN PERSONNEL QUALIF...

Страница 3: ...ronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If...

Страница 4: ...rs 9 2 8 Connecting the GigaCore Redundant Power Supply Unit 10 3 GIGACORE FEATURES EXPLAINED 10 3 1 RlinkX 10 3 2 Groups VLANs 11 3 3 MultiLinkX 12 4 CONFIGURATION 14 4 1 Connecting to the web interf...

Страница 5: ...d send them over the same network Luminex takes care of the rest and makes sure every device receives the right signal ArtNet sACN MANet Dante RAVENNA AES67 Q LAN PTPv2 IEEE1588 2008 and many more A f...

Страница 6: ...wer cable again After connecting the power cable correctly the power LED indicator on the front panel will light up green The GigaCore 26i and GigaCore 26i with PoE requires standard AC power distribu...

Страница 7: ...rt Mode LEDs C PORT LEDS 26x Port Mode According to the selected state the LED will show di erent colours 26x Port Link Speed Shows the current speed and link activity of a port D RJ45 PORTS 24x RJ45...

Страница 8: ...neral status LED Green All OK Green blink Unit is writing to the ash Do not disconnect power Orange Temperature warning Red blink Temperature or Fan error Red Green blink The unit is ashing new rmware...

Страница 9: ...23 and 25 port 14 16 should read 22 24 and 26 Bail wire delatch Bail wire delatch Bail wire delatch Bail wire delatch Dust cap Device shown with dust cap andbailwiredelatch For any other model of mini...

Страница 10: ...job These features will be explained on the following paragraphs 3 1 RlinkX RLinkX which stands for Redundant Link by LumineX is an automat ed system to easily create redundant paths between your Gig...

Страница 11: ...ncluded in a group will be able to communicate with devices in this group only This will result in a better bandwidth and no protocol con ict Three groups have been created in the illustration to the...

Страница 12: ...or data delay The video streams won t be delivered in time and will create lag in the video output The solution MulitiLinkX MultiLinkx enables you to gather several links together and turn them into...

Страница 13: ...will be forwarded to you can have a look at our aggregation planning web page Typethefollowinglinkintotheaddressbarofyourfavouriteweb browser http IPOFMYSWITCH aggregation_code html According to the...

Страница 14: ...rowser Type the IP address of the switch in the address eld and press enter You ll be prompted to enter a login Use admin in the user eld and leave the password eld blank This takes you to the status...

Страница 15: ...the switch will auto assign an IP address in the range 169 254 x x 16 DHCP Dynamic Host Con guration Protocol If your network is equipped with a DHCP server you can enable the DHCP client of the swit...

Страница 16: ...ice back to the default settings but keep all the pro les stored in the pro le manager Press Apply Reset once you have selected the appropriate options for your reset Resetting the device with both ch...

Страница 17: ...from this o set is to restart the switch and thus reset the ber PHYs to eliminate the o set This is needed to have a synchronized system Via the utilities web page of the GigaCore theusercannowchooset...

Страница 18: ...pro le is protected and set as default a padlock will ap pear on slot 1 on the pro le tab 4 3 4 Firmware This menu allows you to upload a new rmware version to the switch Please visit the support sect...

Страница 19: ...ncy is active and operational 4 4 1 Advanced MultiLinkX ouraggregationprotocol hasbeendesignedtowork aw lessly with RLinkX our redundancy protocol To provide users with a more advanced and e cient met...

Страница 20: ...u need to have at least one port on one of the switches set in this group in order to be able to reach the web interface of any of the switches Group 2 to 20 These are the generic groups to be used fo...

Страница 21: ...ocking protocol by timestamping packets at the hardware level With PTPv2 the GigaCore can be part of the clock domain which is necessary for protocols such as AES67 The user can enable disable PTPv2 c...

Страница 22: ...e box Enabled under the text Tagged Management Group VID 1 Press apply to submit the changes 4 6 PoE LU 01 00048 POE only PoE Power over Ethernet is a convenient way to transport both data and power o...

Страница 23: ...ish to modify B Enable or disable these port s C Select the priority for the port s D Apply your new parameters The priority of a port is used when the switch reaches the limit of its maximum output p...

Страница 24: ...e switch the user can select a pro le to export to a computer Then fromthesamecomputer theuserwillbeabletoloadthispro le into an empty slot on another switch Exchanging pro les between switches can be...

Страница 25: ...O THE WEB INTERFACE OF THE SWITCH YOU RE WORKING WITH ALSO PAY ATTENTION THAT THE IP ADDRESS THAT WILL BE RE LOADED WITH THE PROFILE DOESN T CONFLICT WITH AN OTHER IP INTHE NETWORK THE SWITCH SWEB INT...

Страница 26: ...ile the LEDs are blinking red will reset the unit Be aware that releasing the mode button during the rst ve seconds before the LEDs start blinking red will cancel the operation Be aware that releasing...

Страница 27: ...rthestatusLEDsstopped blinking red will cancel the operation Sometimes it is required to get more help with your device or applica tion There is a knowledge base available online that gets updated on...

Страница 28: ...entatives will not be held responsible for any damages to software hardware or data howsoever arising as a direct or indirect result of the product s mentioned herein 7 1 TECHNICAL DATA Mains Voltage...

Страница 29: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 29...

Страница 30: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Отзывы: