Model 4525 Gate Monitor
Operator’s Manual
Ludlum Measurements, Inc.
Page 55
May 2018
Database Logging:
Sets how the occupancies are logged to the database.
The occupancy data can be logged for every vehicle that passes through the
RPM or only for vehicles that alarm. Alarms include both radiation and
over-speed.
Alarm Set Points:
When enabled, the alarm set points are displayed on the
alarm popup and saved to the database.
Enable Automatic Archiving:
When checked, the databases are archived
automatically to the archive folder, and new database files are created. The
archive time can be set to any time but is typically midnight.
Archive Alarm Images Only:
This option determines if all images are copied
to the archive drive or only images that were taken for alarming vehicles.
Backup to Archive Drive:
When enabled, the files created during the archive
are also copied to this drive for backup purposes.
Archive Drive Letter:
The drive letter specifies where the archive data is
backed up. This can be any device that can be mapped to a driver letter and can
include mapped network drives, etc.
Image Save:
Camera images can be stored for all vehicles or alarming vehicles.