Model 4525 Gate Monitor
Operator’s Manual
Ludlum Measurements, Inc.
Page 31
May 2018
buttons to acknowledge the audio, to display the camera image in a larger
window, and a button to view the current occupancy in the Data Viewer
application. The vehicle counters are grouped into inbound and outbound
values. The background readings may be displayed as individual panels or as a
single average of all enabled panels.
If the station is configured as an Echo, then an indicator at the top right of the
screen indicates if the Echo has successfully made a connection to the
Supervisor station. A list box next to the indicator allows the user to change
between different Supervisor stations.
If the camera is enabled, then either a live image is displayed in the image area or
a static image will be displayed. Live images are currently only supported using
IQeye cameras and when the camera streaming option is enabled. When the
camera streaming option is not available or disabled, the main window will
update with a new camera image when a vehicle enters or exits the portal. The
camera image may be triggered when a vehicle enters or exits the RPM. A user-
definable time can be set to allow the image to be triggered up to 9.9 seconds
after the vehicle enters or exits the RPM. If a camera is not enabled, then the
image area displays an animated truck or train image that moves to the left or
right to represent a vehicle in the RPM.
Two indicators are used to represent the infrared sensors and are labeled “S1”
and “S2.” The infrared sensors are used to detect when a vehicle enters the
RPM and to calculate the speed. The indicators will turn red when the infrared
sensors are blocked by an object.
The main screen displays the lane number, user-defined lane caption, and RPM
status in the frame that borders the image area. The following status message
may be displayed:
Connected
: The Supervisor is connected to the RPM and
communicating normally.
Timeout
: The Supervisor has received no data from the RPM in
the last 10 seconds.
Retrying
: The Supervisor is attempting to reconnect to the RPM.
Missing:
The Supervisor was unable to reconnect to the RPM
and will continue trying to connect every 10 seconds.
Rebooting:
The RPM is rebooting.